RAB STEALTH STL360 Instructions Manual Download Page 12

INSTRUCTIONS

STEALTH STL360 INSTALLATION

RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi  cient LED lighting and controls that make it easy for electricians to install

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

TROUBLESHOOTING (

cont’d)

Lights Turn Off  Too Quickly.

1. 

Check if sensor is being “tricked” by refl ected light. If lights 
controlled by the sensor shine or refl ect into the photocell 

(located behind the lens) 

the unit will go on briefl y, see its own 

light, and turn off  “thinking” that it is daytime:

Problems:

Lights refl ect into photocell

Lights shine directly into photocell

Solution:

Adjust 

SUN/MOON

 knob slightly clockwise to allow

operation at higher ambient light levels. Alternatively, move

the lights or refl ectors or mask the lens in the direction of the 
lights and/or refl ections.

2. 

Check if  “R” lamps, non-refl ector “A” lamps or self-ballasted PL 

lamps are being used in non-enclosed lampholder. If so, switch 

to refl ector PAR fl oodlight lamps so the sensor is not aff ected 
by stray light. If using PAR fl oodlights, consider using lower 

wattage, energy saving lamps.

Range Appears Limited.

1.  Check that the sensor is level from side to side and pointed at 

the area you desire. If unit is tilted, part of the detection zone 

may be high in the air over people’s heads.

Solution:

 Position sensor exactly level from side to side 

as shown.

2.  Check that the sensor is not mounted too high. If mounted 

above 20

, much of the usable range will be lost. 

Solution:

 Mounting at 6

 to 10

 allows maximum range.

3.  Check that movement is not directly towards sensor. 

Sensor will see movement across its pattern more quickly. 

To fi x, move the sensor.

4.  Check that movement far away and directly towards sensor is 

not entirely within one zone.

Problem:

 Sensor will not detect until movement crosses zones.

Solution:

 ”Micro Adjust” sensor by moving sideways 1/4

This may move the zones to allow earlier detection.

WRONG

OK!

60'

6-10'

40'

Reduced Range

Maximum Range

20'

More sensitive

Less sensitive

No detection until here

Detection here now

P-73321-RAB Stealth 360

RAB WARRANTY:

 RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty        

PATENT:

 Patent information can be found at rablighting.com/ip

Note:  

These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Easy Answers

rablighting.com

Visit our website for product info

Tech Help Line

Call our experts: 888 722-1000

e-mail

Answered promptly - [email protected]

Free Lighting Layouts

Answered online or by request

© 2023 RAB LIGHTING Inc.

Summary of Contents for STEALTH STL360

Page 1: ...or garage door openers Sensor functions best when the direction of expected movement is across its detection pattern not towards the sensor Mount 6 10 high for optimum range and detection WARNING RIS...

Page 2: ...ghts remain on as long as there is movement within the protection zone Once the zone is vacated lights can be adjusted to remain on approximately 5 seconds up to 12 minutes Since the lights are on onl...

Page 3: ...ge an area does STL360 protect Two powerful detectors combine to give the STL360 180 x 60 long forward range plus superb 360 downward detection below and to all sides as shown in Fig 3 Di cult locatio...

Page 4: ...mounted level from side to side and pointed at the area where you desire coverage If tilted part of the detection zone may be high in the air over people s heads as shown in Fig 12 Fig 8 Fig 11 Fig 1...

Page 5: ...location as shown in Fig 14 Mounting and Wiring Red pigtail is only used to switch remote or additional fixtures as shown in Fig 16 STL360 floodlight kits come pre wired and assembled on the RAB CU4 E...

Page 6: ...silicone sealant around plate and all openings to ensure a weather proof seal Seal all unused conduit entries on surface junction box 9 Install lamps Turn on power Conduct walk test to adjust sensor...

Page 7: ...ell For night only operation turn the knob completely counterclockwise to the MOON symbol For 24 hour operation turn the knob all the way clockwise to the MOON SUN symbol Adjust counterclockwise to ha...

Page 8: ...g 25 Fig 26 Evening Timer Mode Keeps lights on for 1 8 hours after dusk Sensor then reverts to Automatic Mode until dawn If you set the Evening Timer Mode during daylight the sensor will be prepared t...

Page 9: ...ual Override while the sensor is set to 24 hour operation photocell set to MOON SUN lights will come on and remain on continuously Lights will not turn o at dawn Fig 27 Fig 28 WALK TESTING Ready for M...