background image

STEALTH-IN-1114

1. 

Make sure that the sensor is not in Manual Override Mode. Turn sensor 

OFF for 10 seconds, then back ON.  The Sensor will be go through 30 

second warm up period where the lights are one then will go into 

Automatic Mode with lights off and ready to detect movement. 

2. 

Make sure that the sensor is not in Evening Timer Mode. Turn power OFF 

for 10 seconds (see # 1). 

3. 

Make sure sensor is not aimed at or mounted over something that 

would move or change temperature such as waving branches, water, air 

conditioners, windows or heating vents even on neighboring property. 

You can test for infrared sources in the area by placing a box or bag over 

the sensor. Put sensor into test mode. Lights should stay off. Wave your 

hand inside bag in front of sensor. Lights should go on and then time out. 

If sensor operates  

properly when covered, check items # 4-8

 

Problem

: Sensor is triggered by  

unwanted movement or heat source. 

Solution

  (1)  Aim sensor away from movement, or 

  (2)  Mask lens in the direction of the source 

  (3)  Lower sensitivity control setting 

4. 

Make sure sensor and lights are mounted  

firmly and do not move even slightly when  

touched. If they move, tighten all screws. 

5. 

Make sure sensor is not mounted on an  

unstable object such as a tree or pole 

that will move in the wind. 

 

Problem:

 Movement of tree triggers sensor. 

Solution

: Mount on stable surface. 

6. 

Was sensor wired hot (with power on etc)? 

 If so, circuitry may have been damaged. 

7. 

Make sure sensor is not aimed within 20 feet of a road. 

 

Problem

: Passing cars activate sensor. 

Solution

: A 20 foot safety zone and lower sensitivity are  

recommended to avoid activation from passing cars. 

8. 

Make sure heat from lights is not  

triggering sensor. Make sure the  

sensor is below and as far as  

possible away from lights.

Easy Installation & Product Help

Tech Help Line

Call our experts 888 RAB-1000

©2014 RAB LIGHTING Inc.

Northvale, New Jersey 07647 USA

rabweb.com

Visit our website for product info

email

Answered promptly [email protected]

Walk Testing

STL360’s full coverage pattern reduces the need for aiming and adjustment. 

The purpose of the Walk Test is to check and adjust the coverage pattern. The 

STL360 must be manually set into Test Mode (see pg 13).

To enter Test Mode:

Turn Time setting to 5 seconds and turn off sensor for 10 seconds.  After a 
warm up period of 30 seconds the LEDs will be off.

1. 

Aim the sensor at the traffic  

pattern you want to detect.  

Sensor will detect any  

movement ACROSS its  

pattern most effectively. 

2. 

Start outside the pattern and 

walk across the pattern until 

the lights go on. As distance from the sensor increases, it will take more 

movement to be detected. 

3. 

Adjust sensor aiming as necessary to improve coverage. Make sure sen-

sor is level. 

4. 

Sensitivity may be decreased with the SENS knob to detect a limited area 

or if the sensor is being activated by wind, foliage, traffic or animals, or 

increased to cover a larger area. [See pg. 11-12 to adjust sensor settings.] 

The lens mask can also be used to drastically reduce coverage, or allow  

undetected movement from some directions. 

5. 

STL360 is factory set for night only operation. For 24 hour operation, turn 

the photocell control completely toward the SUN/MOON setting. Turn 

counter clockwise to have the sensor come on later at dusk, clockwise to 

have it come on earlier. 

6. 

Repeat steps 1-5 until you are satisfied with coverage. Vacate the  

detection zone for 1 minute and then turn the settings back to desired 

time delay.  Your sensor is now ready for operation.

Technical Tips:

Lights Do Not Turn Off

15

16

Summary of Contents for STEALTH 360

Page 1: ...volts Cautions TURN OFF ALL POWER AT CIRCUIT BREAKER FUSE PANEL Read entire Installation Manual before proceeding All wiring should comply with local electrical codes and requires a qualified electri...

Page 2: ...es Since the lights are on only when needed and the sensor uses only one watt The Stealth is extremely energy efficient Can outdoor lights still be turned on with the light switch Yes STL360 can be co...

Page 3: ...st be located below and as far away as possible from its lights The best location is where the sensor can see all paths of movement The sensor may be wall or soffit mounted As distance from the sensor...

Page 4: ...f the detection zone may be high in the air over people s heads Check that movement is not directly towards sensor Sensor will see movement ACROSS its pattern move quickly Check that move ment far awa...

Page 5: ...ure O Ring gasket is on the screw to attach CU4 EZ Plate to the box 8 Insert plastic Finishing Cap in the center of the CU4 EZ Plate for a weath erproof seal 9 Use silicone sealant around plate and al...

Page 6: ...shown in wiring diagram 9 Twist on wire nuts Secure with electrical tape 10 Make sure all unused openings in CU4 EZ Plate are closed with plugs provided 11 Use silicone sealant around plate and all o...

Page 7: ...nd then off at bedtime To activate the EVENING TIMER flip the wall switch controlling the sensor three times slowly off on off on off on within 3 seconds If you activate the EVENING TIMER during dayti...

Page 8: ...keep lights on for 5 seconds each time it detects movement in its detection zone Perform the walk test and make any adjustments needed Vacate the detection zone for one minunte to end Test Mode Scann...

Page 9: ...is not triggering sensor Make sure the sensor is below and as far as possible away from lights Easy Installation Product Help Tech Help Line Call our experts 888 RAB 1000 2014 RAB LIGHTING Inc Northv...

Page 10: ...ops 8 Moths can be attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 9 Check Solutions 3 4 5 6 7 and 8 under Lights Do Not Turn OFF 1 Check that...

Page 11: ...itive Less sensitive TIME 1 8 HRS 5 SECS 12 MINS EVENING TIMER SENS Technical Tips Lights Turn Off too quickly WRONG OK Technical Tips Range Appears Limited 1 Check that the sensor is level from side...

Page 12: ...r who purchased the product directly from RAB and from no other source b if the product has been installed the entire installation was performed by a licensed electrician or under the supervision of a...