background image

VX/ VXBR CFL INSTALLATION INSTRUCTIONS

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-RAB-1000 or email: [email protected]

TROUBLESHOOTING  

1. 

Is the proper lamp installed? 

2. 

Make sure the lamp is not defective.  Try a lamp known to 
be in operating condition.

3. 

Check that the line voltage at fixture is correct.  Refer to 
wiring directions.

4. 

Is there voltage at the lamp socket?  If there is no voltage, 
check all connections.

5. 

Is the fixture grounded properly? 

ACCESSORIES

Die Cast Guard:

   

 

GD100DG

    GD200DG 

Wire Clamp Flat Bottom: 

 GD100BAR

    GD200BAR

Wire Clamp Round Bottom: 

GD100CL 

    GD200CL

REPLACEMENT  LAMPS  AND  BALLASTS           

 

         RAB Lamp                 RAB Ballast 

Wattage 

         Catalog#               Catalog#                 

Compact Fluorescent Lamp

13 

         LCFL13Q-4P             BCFL13-4E

26 

         LCFL26 

               BCFL42

32 

         LCFL32 

               BCFL42

42 

         LCFL42 

               BCFL42 

LAMP INSTALLATION

CAUTION: Prior to installing, check that the lamp is 

the correct wattage.  Observe lamp manufacturer’s 

recommendations on lamp operation, ballast type and 

burning positions.

1. 

Disconnect power.  Make sure fixture and lamp are cool 

enough to touch.

2. 

Open fixture by unscrewing guard and globe from 

fixture.

3. 

Fully insert the lamp into the socket.

4. 

Replace globe and guard.

5. 

Tighten screws.

WIRING

Use supply wire rated for 90°C. The units are wired for 

120V. Units built for a specific voltage are factory-wired 

for the requested voltage. Make sure the supply voltage 

is compatible with the unit. Multi tap units may be used 

with a choice of 120V, 208V, 240V and 277V, provided 

that proper ballast leads are connected in the field.

1. 

Connect the black fixture lead to the (+) LINE supply lead.

2. 

Connect the white fixture lead to the (-) COMMON supply 

lead.

3. 

Connect the Ground wire from fixture to supply ground.

4. 

All unused leads must be capped and insulated.

CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough to 

touch.  Do not clean or maintain while fixture is energized.

1. 

Clean glass lens with non-abrasive glass cleaning solution.

2. 

As lamps age, light output diminishes.  Mass re-lamping 

at regular intervals ensures full light output at the highest 

efficiency.

Easy Installation & Product Help

Tech Help Line

Call our experts 888 RAB-1000

©2012 RAB LIGHTING Inc.

Northvale, New Jersey 07647 USA

rabweb.com

Visit our website for product info

email

Answered promptly [email protected]

VX/ VXBR CFL-IN 0113

LIGHT

FIXTURE

(+)LINE

BLACK

(-)COMMON WHITE

GROUND

GROUND

Note:  These instructions do not cover all details or variations in 

equipment nor do they provide for every possible situation during 

installation, operation or maintenance.