background image

Caution

• 

All wiring MUST comply with local 
electrical codes and should be installed 
by qualified electrician.

• 

Read entire Installation Manual before 
proceeding.

TURN OFF POWER BY REMOVING 
POWER FUSE OR TURNING OFF CIRCUIT 
BREAKER BEFORE INSTALLATION.

• Total lighting load must not exceed: 

500W LED BULLET12 at 120 Volts 
5 Amps, 450 Watts LED at 120 Volts with    

..   

 0.8pF driver 

5 Amps, 300 Watts LED at 120 Volts with    

..   

 0.5pF driver.  

To switch more wattage, an electrician 
can install an additional relay.

• Line Carrier Remote Control Systems 

such as X-10, Leviton or Radio Shack are 
incompatible with sensors and cause 
false activations.

• Do not install on circuits feeding motor 

loads such as kitchen appliances, HVAC 
equipment, washer/ dryer or garage door 
openers.

• Sensor functions best when movement is 

across its detection pattern, not towards 
the sensor. 
 
 
 
 
 
 
 
 
 

• Mount 6’-10’ high for optimum range and 

direction.

Less Sensitive

More Sensitive

Mounting

1.  Attach the 

Universal Mounting Bar

 with the screws provided to the 

Junction 

Box

. In case of surface mount junction box, use with the 

Metal Surface Plate. 

For 

proper weatherproof seal, apply weatherproof silicone sealant around the edge of 
the Junction Box. This is especially important with an uneven wall surface. 

2.  Use the ‘S’ shaped hands free 

Hanging Hook

 to hold the 

CU4 Plate

 during wiring.

3.  Bring power leads and BULLET12 head leads into 

Junction Box

.

4.  Strip off atleast 1/2” of insulation from all leads, and insert through openings in 

Metal Surface Plate 

(if used).

5.  Attach ground wire to grounding screw on 

Junction Box

. Complete wiring as 

shown in wiring diagram section.

6. Align 

Gasket

CU4 Plate

 and 

Metal Surface Plate

 (for use with surface mounted 

junction boxes) to ensure proper seal. 

7. Tighten 

Center Screw

 (make sure 

O-Ring Gasket

 is on the screw) to attach 

CU4 

plate

 to the box. Check that the 

Gasket

 is fully sealed.

8.  Insert plastic 

Finishing Cap

 in the center of the 

CU4 Plate

 for a weatherproof 

seal. Use silicone sealant on all plugs and unused conduit entries.

9.  Aim BULLET12 heads in the desired direction and tighten locknut and arm screw.

5

4

Assembly and Wiring

Two BULLET12 heads come pre-wired 
and assembled along with SMS500 
sensor on CU4 plate, allowing for 
mounting on round, rectangular or 
octagonal surface or recessed boxes.

1.  Connect the black fixture lead to the 

(+) LINE supply lead.

2.  Connect the white fixture lead to the 

(-) COMMON supply lead.

3.  Connect the GROUND wire from 

fixture to supply ground. 

4.  Red pigtail is only used to switch 

remote or additional fixtures.

Black

Black

Red

   

Red 

(pigtail)

Ground

Ground

Power In

White

White

O-Ring Gasket

CU4 Plate

Gasket

Plug

Center Screw

Finishing 

Cap

Metal 

Surface 

Plate

Hanging 

Hook

Universal 

Mounting 

Bar

Bar 

Screws

Junction Box 

(not supplied)

.

Summary of Contents for SMSBULLET2X12

Page 1: ...Installation Manual SMARTBULLET SMSBULLET2X12 1...

Page 2: ...ecision molded Lexan Color Matched Lens Dark lens with black units White lens with white units Surge Protection Withstands up to 3000 Volts Manual Override Double flip wall switch logic prevents activ...

Page 3: ...ree Hanging Hook to hold the CU4 Plate during wiring 3 Bring power leads and BULLET12 head leads into Junction Box 4 Strip off atleast 1 2 of insulation from all leads and insert through openings in M...

Page 4: ...tivity and Photocell adjusted TimeControl Sets the time that lights will remain on after the Detection Zone is vacated from approximately 5 seconds to 15 minutes Use the adjustment tool provided to tu...

Page 5: ...Pattern The sensor has a Double Look Down Lens with one Look Out zone and two Look Down zones for excellent detection both at long and close range Detection extends out a maximum of 30 feet and is 18...

Page 6: ...lights 1 Make sure sensor is not aimed at something that would move or change temperature such as waving branches water air conditioners windows or heating vents even on neighboring property You can t...

Page 7: ...ire the sensor to operate both in low level light and at night turn the Photocell Control knob clockwise to the sun symbol 3 Check that lights from other sources such as adjacent porch lights garden l...

Page 8: ...roduct was purchased by the contractor or end user from an authorized RAB distributor who purchased the product directly from RAB and from no other source b if the product has been installed the entir...

Page 9: ...roduct Help Tech Help Line Call our experts 888 RAB 1000 2014 RAB LIGHTING Inc Northvale New Jersey 07647 USA rabweb com Visit our website for product info email Answered promptly sales rabweb com SMS...

Reviews: