![background image](http://html.mh-extra.com/html/rab-lighting/rddled2r/rddled2r_installation-instruction_3110876005.webp)
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
REMODELER & NEW CONSTRUCTION TRIMLESS
2IN 10W ROUND & SQUARE INSTRUCTIONS
Fig: 3
SPACKLED FLANGE MOUNTING
1. Place
Spackle Flange
on ceiling and align the opening
with the ceiling cutout. Carefully mark the (4) hole
pattern on ceiling and remove
Spackle Flange
.
2. For New Construction (Fig: 3): Use a 7/32” drill bit to drill
ceiling typical 5/8” ceiling depth. Align rib of
Spackle
Flange
to rib in
Rough-in
. Insert the
Spackle Flange
and
secure with 8-32 x 1-1/2” flat head counter shank machine
screws.
NOTE: DO NOT DRILL HOLES DEEPER THAN THE
CEILING THICKNESS.
3. For Remodeler Unit (Fig4): Use 5/16” drill bit and drill
ceiling at 4 marked places. Install
Wall Anchors
and
secure
Spackled Flange
with 8-32 X 1-1/4” flat head
counter shank sheet metal screws.
4. Apply joint compound to spackle frame edge. Remove
Dust protector
and remove small debries and make it
flush to ceiling.
Wall Anchors (4)
Fig: 4
WALLWASH MOUNTING
1. For the Wallwash Model, orient the fixture such that
the
Lens such that the thin section
is aimed in correct
orientation.
2. If necessary, rotate of the wall wash lens to orient in
certain direction.
Spackled Flange
Ceiling
Fig: 5
Spackled Flange
Ceiling
This side away
from wall
Wall Wash lens
WIRING
RISK OF FIRE
. Universal voltage driver permits operation
at 120V thru 277V, 50 or 60 Hz. Drop down supply wires
must be at least 9” long to allow fixture removal. For Non-
Dimming (on/off), Electronic Low Voltage (ELV) and Triac
Dimming follow the wiring directions in Fig. 6. For 0-10V
dimming, Fig. 7.
1. Connect GROUND wire from fixture to supply ground.
2. Connect black fixture lead to the (+) LINE supply lead.
3. Connect white fixture lead to the (-) COMMON supply lead.
Fig: 7
Fig: 6
TROUBLESHOOTING
1. Check that the line voltage at the fixture is correct. Refer
to wiring directions.
2. Is the fixture grounded properly?
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to
touch. Do not clean or maintain while fixture is energized.
1. Do not open fixture to clean the LED. Do not touch
the LED.
2. Do not touch reflector, lens or trim cone.
3. Do not clean any fixture surface with wood base cleaning
material such as paper towels or tissues.
8/32 X 1-1/4” counter
shank sheet metal
screws (4)
8-32 x 1-1/2” counter
shank machine screws
(4)