background image

LOTBLASTER    65W 110W 160W INSTALLATION 

INSTRUCTIONS

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-RAB-1000 or email: [email protected]

  ™

Easy Installation & Product Help

Tech Help Line

Call our experts 888 RAB-1000

©2016 RAB LIGHTING Inc.

Northvale, New Jersey 07647 USA

rabweb.com

Visit our website for product info

email

Answered promptly [email protected]

Note:  These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during 

installation, operation or maintenance.

LOTBLASTER 65 110 160 IN 1216

Pending: Patent pending  

TROUBLESHOOTING 

1.  Check that the line voltage at the fixture is correct.  Refer 

to wiring directions.

2.  Be sure the fixture is grounded properly.
3.  Ensure the photocell, if used, is functioning properly.

CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough 

to touch. Do not clean or maintain while fixture is 

energized.

1. 

Lens should be washed in a solution of warm water and 

any mild, non abrasive household detergent, rinsed with 

clean water and wiped dry.

2. 

Do not open fixture to clean the LED. Do not touch the 

LED.

0-10V DIMMABLE WIRING

Universal voltage driver permits operation at 120V thru 

277V, 50 or 60 Hz. 0-10V control wires must be rated for 300V 

minimum. Units ordered with (/480/D10) suffix operate at 

480V, 50Hz/ 60Hz. Follow the wiring directions as shown in 

figure below.

1. 

Connect the black fixture lead to the LINE supply lead.

2. 

Connect the white fixture lead to the COMMON supply 

lead.

3. 

Connect the GROUND wire from fixture to supply ground. 

Do NOT connect the GROUND of the dimming fixture to 

the output.

4. 

Connect the purple fixture lead to the (V+) DIM lead.

5. 

Connect the gray fixture lead to the (V-) DIM lead.

6. 

 Cap the yellow fixture lead, if present. Do NOT connect.

BILEVEL DIMMER OPTION

For 100% light output (disabling the dimmer), splice red wire 

with black line wire.
For chosen output only, leave red wire capped.
For Bilevel Function, connect red wire to switched device. 

Determine what % light output is desired and set switch prior 

to installation. Options are: 25%, 50%, and 75%.

RECEPTACLE OPTION

Units ordered with (/PCT) suffix is supplied with 3 wire 

receptacle and 120-277V Twistlock Photocell. Units 

ordered with (/PCT4) is supplied with 3 wire receptacle 

and 480V Twistlock Photocell.
Units ordered with (/5PR) suffix is supplied with 5-Pin 

receptacle without photocell. Units ordered with 

(/7PR) suffix is supplied with 7-Pin receptacle without 

photocell. Brown and Orange wires from the 7-Pin 

receptacle are not connected and are reserved to DALI 

or other control systems.

Summary of Contents for LOTBLASTER 65W

Page 1: ...thers if any can withstand the weight of the fixture LOTBLASTER WITHOUT UNIVERSAL POLE ADAPTER LOTBLASTER WITH UNIVERSAL POLE ADAPTER MOUNTING FIXTURE DIRECTLY TO POLE Follow steps below to mount the Housing to RAB square pole and check that pole is drilled according to Pole Drawing Detail 1 Loosen Cover Screw 2 to open the Housing 2 Feed supply wires from center opening of Pole not supplied into ...

Page 2: ...opening of Square Pole through gaskets and UPA 5 Thread 3 Bolts 2 along with washers and lockwashers supplied through UPA and tightly secure to Variable Bolster Plate 6 Insert the Screw Cover MOUNTING FIXTURE TO UNIVERSAL POLE ADAPTER Follow steps below to mount the Housing to Universal Pole Adaptor UPA 1 Tightly secure 1 1 4 Bolts 2 to Housing from the outside as shown below until they bottom out...

Page 3: ... supplied Refer to Variable Bolster Plate Detail regarding drill hole spacing on pole 1 Adjust Bracket on Variable Bolster Plate to desired bolt spacing and tighen Screw 2 Refer to Variable Bolster Plate Detail for more information 2 For Round Pole not supplied use Gasket for Round Pole Discard Gasket for Square Pole 3 Line up Universal Pole Adaptor UPA Gasket for Round Pole top hole on the Round ...

Page 4: ... 0 10V DIMMABLE WIRING Universal voltage driver permits operation at 120V thru 277V 50 or 60 Hz 0 10V control wires must be rated for 300V minimum Units ordered with 480 D10 suffix operate at 480V 50Hz 60Hz Follow the wiring directions as shown in figure below 1 Connect the black fixture lead to the LINE supply lead 2 Connect the white fixture lead to the COMMON supply lead 3 Connect the GROUND wi...

Page 5: ...he House Side Shield LTHS 2 to Lotblaster Housing 1 Remove Screws 8x2 from Lens 2 using Center Pin Torx Screwdriver not supplied 2 Orient the LTHS 2 as shown below on Lens 2 Ensure the shield is towards the mounting surface pole Warning Do NOT remove or change orientation of the Lens 2 3 Tightly secure Screws 8x2 LTHS 2 CLEANING MAINTENANCE CAUTION Be sure fixture temperature is cool enough to tou...