3
Locate the LOS800CA where it has
an unobstructed view of the room,
particularly the areas normally
occupied by people. Ideal mounting
height is 3.5 to 4.5 feet above
the floor.
If people cannot see the sensor
lens from their normal positions in
the room, the sensor will not detect
their presence.
High cabinets, walls, doors and other
obstructions may limit the sensor’s
view of the entire room. If obstructions
can be moved the sensor will have a
better view. If the areas obstructed
are not areas normally occupied,
the sensor will still be able to see
normal occupancy.
Cabinet obstructs sensor’s
view of active area
Obstruction moved, sensor
has full view
Do not locate sensor over or looking at
heating vents, baseboard, heaters,
hanging plants or air conditioners.
Do not locate sensor where it will view
direct sunlight.
If the sensor’s location gives it a view
of the other rooms or hallways, lights
will be turned on when movement is
detected in these adjacent areas. If this
is undesirable, the sensor’s detection
zone may be restricted by covering a
portion of the lens with a white paper
label or tape.
Sensor has view of
adjacent area
Wiring:
Replaces single pole wall switch.
3 wire system where neutral & hot
are present.
Temperature Range:
-4°F to 104°F
(-20°C to +40°C)
Humidity Range:
93% relative humidity.
Approvals:
UL Listed Photocontrol
UL Standard 773A
Weight:
3.3 oz. no box. 5 oz. with box.
Parts List:
LOS800CA Sensor
Matching wall plate
2 matching wall plate screws
2 sensor mounting screws
3 wire nuts
Dimensions:
A= 4.2” (107mm)
B=1.8” (46mm)
C= 1.6” (41mm)
D= 2.63” (67mm)
E= 1.3” (33mm)
F= 0.5” (13mm)
G= 1.1” (28mm)
D
B
E
C
G
F
2
A
Sensor
Sensor
1. Selecting a Location
Specifications
Sensor
5’
32’
Side View
32’
Coverage:
1000 square feet, up to 32’ from
the sensor.
Detection Zone:
180° in 18 zones
32’ range.
Detection Pattern:
Time Adjustment:
5 seconds to 15 minutes after motion
stops (approximate)
Detection Indicator:
Red LED when motion is detected.
Green LED in Auto Mode.
LED Off when Manual On is required
(15 minutes after vacating the room).
Energy Codes:
Complies with California Title 24
Switching Capacity:
120V: 800W Incandescent &
Fluorescent, 6.67 Amps
277V: 1200W Incandescent &
Fluorescent, 4.33 Amps.
Minimum Load:
None