Features

Maximum Energy Savings

Sensitive 180° view passive 
infrared motion detector keeps 
lights on only when rooms are 
in use.

Manual ON switch with automatic 
OFF saves energy!

Meets California Title 24 standards.

Maximum Coverage

180° wide angle detection pattern.

Lights have to be manually switched
on when someone enters the room .

Covers 1000 square feet, eliminates
the need for multiple sensors.

Superb small movement sensitivity
within 18 feet. Great for sedentary 
office use.

No dead spots within 18 zones.

Easy Installation

Works with electronic ballasts.

No minimum load requirement.

Replaces single pole wall switches
without additional wiring.

Decorator style, rectangular switch
plate included.

Only 1/2” protrusion from switch plate. 

Maximum Versatility

Switches all types of fluorescent and/or 
incandescent lighting.

Fits single or multi-gang boxes without 
special adapters.

Summary of Contents for LOS800CA

Page 1: ...meone enters the room Covers 1000 square feet eliminates the need for multiple sensors Superb small movement sensitivity within 18 feet Great for sedentary office use No dead spots within 18 zones Easy Installation Works with electronic ballasts No minimum load requirement Replaces single pole wall switches without additional wiring Decorator style rectangular switch plate included Only 1 2 protru...

Page 2: ...e sensor s detection zone may be restricted by covering a portion of the lens with a white paper label or tape Sensor has view of adjacent area Wiring Replaces single pole wall switch 3 wire system where neutral hot are present Temperature Range 4 F to 104 F 20 C to 40 C Humidity Range 93 relative humidity Approvals UL Listed Photocontrol UL Standard 773A Weight 3 3 oz no box 5 oz with box Parts L...

Page 3: ...e On button the LED will be Green and the sensor will enter Auto Mode When it detects movement the LED alternates between Red and Green and the lights will turn on 7 When detection stops the sensor turns off the lights in about 8 seconds while set at minimum 8 Check coverage area 9 Set the timer to desired amount from 5 seconds to 15 minutes 10 After the lights go out and the sensor does not detec...

Page 4: ... 5 Troubleshooting Lights Do Not Turn On 1 Check that the lamps and fixtures work wiring exactly matches the wiring diagram wiring polarity is correct power is on sensor has warmed up for 40 secs 2 Make sure sensor s view of the room is not blocked Lights Do Not Turn Off 1 Check that the Time delay control is set to minimum 2 Stay completely out of the protection pattern to avoid activation 3 Make...

Page 5: ...ease include your sales receipt and a description of the problem If your unit is out of warranty or the damage is unrelated to its original manufacture return your unit directly to RAB with a check for 20 00 payable to RAB Lighting We will repair or replace the unit Under no circumstances shall we be liable for any incidental or conse quential damages arising out of or in connection with the use o...