Any wires not in use must be capped o
ff
or otherwise insulated.
REPEATER:
Disables zone control and power measurement, and
extends the range of your network.
POWER MEASUREMENT:
The Lightcloud Controller is capable of
measuring the power usage of the attached circuit. In order to utilize
this function, the neutral wire of the load must be connected to the
white-red sense wire. If the Switched Neutral line cannot be used, it
should be tied to the regular neutral wires (i.e. all neutral wires joined).
POWER LOSS DETECTION
: If mains power to the Controller is lost,
the device will detect this and alert the Lightcloud application.
EMERGENCY DEFAULT:
If communication is lost, the Controller may
optionally fall back to a specific state, such as turning the attached
circuit on.
!