FXLED    200W 300W INSTALLATION INSTRUCTIONS

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-RAB-1000 or email: [email protected]

®

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding 

is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A 

PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.

SLIPFITTER MOUNTING

1.  The slipfitter mounting fits a 2 3/8” O.D. 

Tenon

. Place the 

slipfitter over the

 Tenon

 and secure the fixture with the 

Set Screws

 (2) on the side of the slipfitter.

2.  Remove two screws on side of 

Cover Plate

. Remove the 

Cover Plate

 and adjust the angle of the fixture.

3.  Loosen the 

Locking Bolt

 and swivel fixture to desired 

angle.

4.  Tighten the 

Locking Bolt

 and re-attach 

Cover Plate.

Tenon

Set Screws (2)

Cover Plate

Locking Bolt

Pivot Bolts

TRUNNION MOUNTING

CAUTION

: UL and C-UL listed or CSA certified liquid tight 

cord grip suitable for use with STW flexible cord shall be 

used for connection to a wet location outlet box provided 

by others.
To adjust the angle of the fixture using the trunnion:
1.  Loosen the 

Pivot Bolts

 & angle locking screw.

2.  Adjust fixture to desired angle.
3.  Tighten 

Pivot Bolts

 & angle locking screw.

ACCESSORIES

Chrome Wire Guard:

   

 

GDFXLED300W

Poly Shield:

  

 

GDFXLED300P

Lens & Door Replacement:

 

LFFXLED300A (bronze)

    LFFXLED300W 

(white)

WARNING: RISK OF SERIOUS INJURY OR DEATH!

DO NOT MOUNT THE SLIPFITTER TO A TENON OR BRACKET THAT IS MORE THAN 20 DEGREES FROM VERTICAL. MOUNTING 

AT ANY ANGLE OTHER THAN 0-20 DEGREES INCREASES THE RISK OF DISENGAGEMENT AND/OR FAILURE OF THE 

SLIPFITTER. INSTALL THE POLE ON A SECURE BASE OR INSTALL THE BRACKET TO A WALL FIRST. THEN PLACE LUMINAIRE 

ONTO THE POLE OR BRACKET. DO NOT LIFT ASSEMBLED LUMINAIRE OR POLE OR LUMINAIRE & BRACKET. LUMINAIRE OR 

POLE/BRACKET’MAY 

DISENGAGE.

Slipfitter

Summary of Contents for FXLED

Page 1: ...Plate Remove the Cover Plate and adjust the angle of the fixture 3 Loosen the Locking Bolt and swivel fixture to desired angle 4 Tighten the Locking Bolt and re attach Cover Plate Tenon Set Screws 2 C...

Page 2: ...from fixture to supply ground LIGHT FIXTURE LINE BLACK COMMON WHITE GROUND GROUND Fig 1 Fig 2 0 10V DIMMABLE WIRING Universal voltage driver permits operation at 120V thru 277V 50 or 60 Hz For fixture...

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ...Manual...

Page 22: ...ment batteries CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO LOCAL LAWS Some communities offer recycling or collection of rechargeable ba...

Page 23: ...teway Lightcloud Devices Finding a Suitable Location Best Practices Best Practices Getting Started Installation Lightcloud Gateway Lightcloud Devices Table Setup Network Setup Gateway Activation Light...

Page 24: ...4...

Page 25: ...charge of your lighting from sensing to dimming schedules to scenes and everything in between Control and configure your system remotely using the Lightcloud Application or call RAB to have our expert...

Page 26: ...twork which allows site layout to be flexible and robust The Lightcloud Gateway and Devices require a subscription to function beyond the installation period Call RAB at 1 844 LIGHTCLOUD or visit ligh...

Page 27: ...r Lightcloud site is at your command with the Lightcloud Application For maximum security the Gateway isn t exposed to the internet at all and for maximum reliability the Gateway contains an Uninterru...

Page 28: ...sensor that measures available light and adjusts your lighting automatically Lightcloud Ceiling Sensor The Ceiling Sensor is an intelligent passive infrared motion sensor that can be configured for bo...

Page 29: ...nes when installing additional Lightcloud devices If there is a clear line of sight between two devices they can be placed up to 1000 feet apart If the two devices are separated by ordinary drywall co...

Page 30: ...cloud Daylight devices do not extend the range of a Lightcloud network Lightcloud Gateway 100 ft Add an additional Lightcloud Device to extend network range around corners BRICK CONCRETE OR METAL WALL...

Page 31: ...S A M P L I F I E R S A N T E N N A S PROBLEM DEVICES SIGNALS Lastly consider sources of invisible interference Avoid placing Lightcloud devices near microwaves motors especially elevator mechanical...

Page 32: ...EVICE ID ZONE NAME PANEL CIRCUIT PWR ENGY DIM NOTES CONTAINS 2x Wire Nuts 2x Mounting Screws 4x Device ID Labels 1x Power Cable The Lightcloud Gateway must be mains powered for permanent installation...

Page 33: ...You must move the Gate way to a location with better cellular signal Solid Yellow Adequate cellular signal This signal strength works for most applications but if possible move to a location with bett...

Page 34: ...t blade screwdriver and hammer Place the screw driver blade at the edge of the KO then tap the screwdriver with the hammer to weaken the attachment Work your way around the edge of the KO until it bre...

Page 35: ...unction box use the junction box s included screws NOTE Conduit must be used to connect to side knockouts 4 Turn breaker back on ON ON 6 STEP FOUR STEP FIVE STEP SIX Install included battery with nega...

Page 36: ...nal strength LED is yellow or green If the Gateway is powered but this LED is not lit relocate the Gateway to an area with better reception You can use the included power cable to easily test the sign...

Page 37: ...ller s 0 10V dimming wires place a checkmark here Lightcloud Devices Lightcloud devices that are mains hard wired powered are designed to be installed on a junction box or similar enclosure and must b...

Page 38: ...to your Lightcloud network call RAB at 1 844 LIGHTCLOUD Software Setup Lightcloud is cloud based no software to install or maintain ever Once you have a Lightcloud account you can login to lightcloud...

Page 39: ...will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is e...

Page 40: ......

Page 41: ...HELP RAB Lighting Inc 170 Ludlow Avenue Northvale NJ 07647 Custom manufactured in China 1 844 LIGHTCLOUD 1 844 544 4825 Lightcloud is a commercial wireless lighting control system service It s powerf...

Page 42: ...tcloud Dimmer is an in wall switch that connects wirelessly to a Lightcloud Controller to provide switching dimming and scene control Hello Product Features Wireless Control Configuration Zone Switchi...

Page 43: ...1 77 W x 2 7 H x 1 49 D Faceplate 2 94 W x 4 69 H x 0 06 D Faceplace Bracket 2 8 W x 4 55 H x 0 13 D 18AWG grounding terminals supporting up to 12AWG wire WIRELESS RANGE Line of Sight 1000 feet Obstru...

Page 44: ...ould only be installed by a qualified electrician and in compliance with local and national electrical codes This product should only be installed in a UL approved single gang wall box enclosure Indoo...

Page 45: ...other device to the network If there is a clear line of sight between two Lightcloud devices they can be placed up to 1000 feet apart If the two devices are separated by ordinary drywall construction...

Page 46: ...ew the line black and neutral white wires into the labeled connectors on the back of the Dimmer Connect the ground wire green 2b Use the two 6 32 1 2 Phillips round head screws to secure the Dimmer to...

Page 47: ...e faceplate onto the faceplate bracket 2c Use the two 6 32 5 16 Phillips flat head screws provided to secure the faceplate bracket to the Dimmer Setup Installation cont d 2 Install the Lightcloud Dimm...

Page 48: ...dimming DEVICE IDs ZONE NAME PANEL CIRCUIT 3 Labeling your device 4 Power up To add your Lightcloud Dimmer to your system enable Setup Mode via the Lightcloud application or call RAB at 1 844 544 4825...

Page 49: ...rce device to leave current Lightcloud network DIM LEVEL INDICATOR Displays current dim level Zone mode NIGHTLIGHT White Lit when zone is off so you can find the dimmer SIGNAL STRENGTH INDICATOR Indic...

Page 50: ...een tested and found to comply with the limits for Class B digital devices pursuant to Part 15 Subpart B of the FCC rules These limits are designed to provide reasonable protection against harmful int...

Page 51: ...tured in China 1 844 LIGHTCLOUD 1 844 544 4825 support lightcloud com Lightcloud is a commercial wireless lighting control system service It s powerful and flexible yet easy to use and install Learn m...

Page 52: ...t installed and used in accordance with the instruction manual may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular ins...

Page 53: ...d Daylight Instruction Manual Mounting Screws Straight Angled Mounting Brackets Power Supply for Setup USB Cable for Setup What You Need Lightcloud Gateway A Lightcloud installation requires at least...

Page 54: ...ork plug it in with the included Micro USB power adapter The white Power Indicator will come on and the Device Status Indicator will blink red every 10 seconds until it is joined to your network For s...

Page 55: ...le if there s enough of it 3 Find a Suitable Location Example of ideal placements 3a A skylight is a great location for the Lightcloud Daylight Be aware of where shadows will land throughout the day a...

Page 56: ...re it ends up in direct sunlight as much as possible 3d DIRECT SUNLIGHT Use angled bracket to get more direct sunlight DIRECT SUNLIGHT May need to use an extension to obtain direct sunlight CEILING WI...

Page 57: ...plication will show the last measured light level so you can configure actions to take at different levels Or simply call or email us 5 Configure 1 844 LIGHTCLOUD 1 844 544 4825 support lightcloud com...

Page 58: ...B powered Force device to leave current Lightcloud network Hold for 10 seconds while connecting USB power Reset to factory defaults and leave current network DAYLIGHT HARVESTING Daylight Harvesting is...

Page 59: ...Welcome LCCONTROL20 D10 Controller 1 844 LIGHTCLOUD 1 844 544 4825 support lightcloud com WE RE HERE TO HELP...

Page 60: ......

Page 61: ...ronic Ballast or LED 277VAC 20A Magnetic Resistive 240VAC 5A Tungsten Electronic 20A FLA 60 LRA 2HP 120VAC 15A Tungsten 1HP OPERATING TEMPERATURE 40 C to 40 C OVERALL DIMENSIONS 1 55 diameter 5 75 len...

Page 62: ...What You Need Lightcloud Gateway A Lightcloud installation requires at least one Lightcloud Gateway to manage your devices 1 844 LIGHTCLOUD or 1 844 544 4825 support lightcloud com WE RE HERE TO HELP...

Page 63: ...neutral line for the load being switched This enables power measurement See the Power Measurement section under Functionality for more information BLACK WHITE RED 0 10V DIMMING Panel Controller Lightc...

Page 64: ...placed up to 1000 feet apart If the two devices are separated by ordinary drywall construction try to keep them within 100 ft of each other Brick concrete and steel construction may require additiona...

Page 65: ...ave an equal or better insulation rating You may need to complete your low voltage wiring in another enclosure or use a partition 0 10V is a common method of low voltage control of dimmable drivers an...

Page 66: ...or Trough Space and code allowing you may install Lightcloud devices directly in your breaker box or lighting panel Alternatively break out lighting circuits and install Lightcloud devices in a separa...

Page 67: ...a building manager Attach the Device Identification stickers included with each device to a row then write in additional information such as Zone name Panel Circuit Number and whether or not a zone u...

Page 68: ...5 STATUS INDICATOR SIGNAL INDICATOR Confirm Device Connectivity Illuminated when device is powered Press once to highlight this device in the Lightcloud Application Press twice and hold to set dim lev...

Page 69: ...e zone TRIGGER Detect when an attached circuit is open or closed For example you could attach the Controller in Trigger mode to an existing occupancy sensor to allow your Lightcloud system to react to...

Page 70: ...e this function the neutral wire of the load must be connected to the white red sense wire If the Switched Neutral line cannot be used it should be tied to the regular neutral wires i e all neutral wi...

Page 71: ...ill not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is en...

Page 72: ...NJ 07647 Custom manufactured in China 1 844 LIGHTCLOUD 1 844 544 4825 support lightcloud com Lightcloud is a commercial wireless lighting control system service It s powerful and flexible yet easy to...

Page 73: ...nufactured in China 1 844 LIGHTCLOUD 1 844 544 4825 support lightcloud com Lightcloud is a commercial wireless lighting control system service It s powerful and flexible yet easy to use and install Le...

Page 74: ...ive infrared motion sensor that can switch and dim both hard wired circuits and remote circuits using Lightcloud Controllers Hello Product Features Advanced PIR Sensing Secure Cloud Control Configurat...

Page 75: ...NG HUMIDITY 10 RH to 95 RH Non Condensing OVERALL DIMENSIONS 4 91 Diameter 1 61 Height WIRELESS RANGE Line of Sight 1000 feet Obstructions 100 feet Warranty is active as long as service plan is active...

Page 76: ...ling devices If there is a clear line of sight between two Lightcloud devices they can be placed up to 1000 feet apart If the two devices are separated by ordinary drywall construction try to keep the...

Page 77: ...e to a row then write in additional information such as Zone name Panel Circuit Number and whether or not a zone uses dimming ZONE NAME PANEL CIRCUIT INSTALL AT A JUNCTION BOX INDOOR OUTDOOR The Ceili...

Page 78: ...ty Confirm Status Indicator is solid green If it is not make sure your device is within range of another Lightcloud AC powered device To add new devices to your Lightcloud network call RAB at 1 844 LI...

Page 79: ...o sensor by pushing up and twisting to the right clockwise 7 Commission Configure Your Devices All Lightcloud products can be commissioned and configured by Logging on to lightcloud com Calling RAB at...

Page 80: ...ATOR After the Device Button has been pressed this indicator illuminates when the device receives a message and indicates the strength of the signal 3 Best Signal 2 Acceptable Signal 1 Unacceptable Si...

Page 81: ...be used via Lightcloud Automations to control other devices CONTROLLER MODE In Controller Mode the attached circuit is controllable as an independent zone in the Lightcloud application Motion detecti...

Page 82: ...ation This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interfe...

Reviews: