background image

Fixture should not be recessed.

LOCATION

FLEX FLOOD

Wall Mount Installation Instructions

WIRING

All units are factory wired for 120v. If voltages other than 120V are
required, Remove the reflector and rewire for the appropriate voltage.
1. Connect the appropriate BLACK fixture lead to the

(+) LINE supply lead.

2. Connect the WHITE fixture lead to the (-) COMMON 

supply lead.

3. Fixture ground wire must be connected to supply ground.
4. All unused leads must be capped and insulated.

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

RAB fixtures must be wired in accordance with the National Electrical Code and and all applicable local codes. Proper grounding
is required for safety. 

WARNING:

MAKE CERTAIN POWER IS 

OFF

BEFORE INSTALLING OR MAINTAINING FIXTURE

LAMP INSTALLATION

Caution: 

Prior to installing, check that the lamp is of proper type and wattage. Observe lamp

manufacturer’s recommendations on lamp operation, ballast type and burning positions.

1. Disconnect power. Make sure fixture and lamp are cool enough to touch.
2. Open fixture by removing the 4 door screws. Swing lens door down on hinges.
3. Insert lamp.
4. Before closing lens door make sure frame gasket is properly seated all around fixture.
5. Close door. Tighten 4 screws.

REPLACEMENT LAMPS:

High Pressure Sodium

ANSI              Metal Halide

ANSI        

Wattage

Catalog #

Code              Wattage

Catalog #

Code       

70

LHPS70

S62                    50

LMH50

M110

100

LHPS100

S54

70

LMH70

M98

150

LHPS175

S55

100                LMH100           M90
150

LMH150PS

M102

150                LMH150            M107

175                LMH175           M57

Fluorescent

Wattage        Catalog #

42                 LCFL42 

CLEANING

Clean reflector and glass refractor with nonabrasive glass
cleaning solution or detergent. Rinse with clean water.

Caution: Be sure fixture temperature is cool enough
to touch.

TROUBLESHOOTING CHECKLIST:

1. Proper lamp is installed. Lamp is not faulty.
2. Fixture is wired properly.
3. Line voltage at the fixture is proper.
4. Fixture is grounded properly.

0˚ Down 

0˚ Up 

30˚Up 

30˚ Down 

Thank you for buying RAB lighting fixtures. Our aim is to design the best quality products so you can get the job done right. 
We’d like to hear your comments. Call us at 888-RAB-1000, attention Marketing Department or email: [email protected].

LIGHT

FIXTURE

(+) LINE     BLACK

(–) COMMON       WHITE     

GROUND

SUPPL

Y

GROUND

GROUND

GROUND

RAB 

LIGHTING  Tel: 888 RAB-1000 • Fax: 888 RAB-1232 • www.rabweb.com