Calibration of the Voltages on the Telemetry connector
The VJ’s internal Telemetry connector gives to the external the voltages referred
to the various values under control. The voltage related to the Forward Power
output is 1,6V for 1KW. To calibrate this voltage follow the procedure below:
1-
Adjust the power of the machine to the nominal value of 1KW.
2-
Adjust R13 on the Telemetry Card to obtain a voltage, between pin 16 and
pin 1 of Telemetry connector, of 1,6V.
The pin 4 gives the voltage referred to measurment of the Reflected Power. This
voltage is 1,4V for 100W (10% of 1KW). To calibrate this voltage follow the
procedure below:
1-
Adjust the Reflected Power to 100W using a wattmeter Bird in output.
2-
Adjust R14 of Telemetry Card to obtain a voltage, between pin 14 and pin 1
of connector, of 1,4V.
3-
Adjust R36 to set the Power Good threshold.
10.2
Wiring Connections details
1- The exciter is not supplied from the Service Connector but separataly. This is
because if there was no high voltage, the Service Connector would be not
supplies instead, too. The exciter shall be ever ON.
2- A system that closes to earth a BNC contact when the machine is in Standby
mode is used. This contact is connected with a BNC-BNC cable to the Interlock/
RF Mute connector of the exciter. When the VJ goes in Standby status, the
exciter enters in RF Mute mode. The contact that permits this functionallity is
located on the Service teleswitch.
3- A Reset (or Restart) button is connected between pin 9 and earth of Telemetry
Card JP2 connector and it’s located on the front panel. It’s used to give the
same kind of signal as the an exciter that an PTXLCD gives when it is switches
ON. This operation resets the alarms and the remote control relay, in case the
amplifier is in OFF status and there is not an exciter able to change it to the ON
status.
4- The Alarms Card is supplied by the alternate current that first passes throught
JP3 (pin 1 and 2) of telemetry. When the Telemetry Card receives the REMOTE
OFF command, Alarms Card turns OFF itself. This permits to remotly reset the
alarms throught an ON-OFF-ON sequency. Please remember that after 6
attempts failed the machine will block itself. This remote control system gives
a remote reactivation mechanism.
5- A green LED is mounted between the point S of the Alarm Card and ground
(throught a 2K2 resistor); this is to indicate whether the Alarms Cards is supplied
Summary of Contents for VJ1000HP
Page 1: ...Prodotto da Italia VJ1000HP User Manual...
Page 4: ...This page intentionally left blank...
Page 20: ...VJ1000HP 14 40 USER MANUAL Rev 4 0 26 02 01 FIG 1...
Page 22: ...VJ1000HP 16 40 USER MANUAL Rev 4 0 26 02 01 FIG 2...
Page 24: ...VJ1000HP 18 40 USER MANUAL Rev 4 0 26 02 01 PHOTO 1 3 1 2 5 7 11 9 4 6 8 12 10...
Page 26: ...VJ1000HP 20 40 USER MANUAL Rev 4 0 26 02 01 PHOTO 2 1 2 3 4 5 6...
Page 28: ...VJ1000HP 22 40 USER MANUAL Rev 4 0 26 02 01 PHOTO 3 7 2 3 6 5 4 1...
Page 40: ...VJ1000HP 34 40 USER MANUAL Rev 4 0 26 02 01 SETUP 1 FIG 3...
Page 41: ...VJ1000HP 35 40 USER MANUAL Rev 4 0 26 02 01 SETUP 2 FIG 4...
Page 42: ...VJ1000HP 36 40 USER MANUAL Rev 4 0 26 02 01 SETUP 3 FIG 5...
Page 46: ...VJ1000HP 40 40 USER MANUAL Rev 4 0 26 02 01 This page intentionally left blank...
Page 47: ...VJ1000HP Flat Cable 1 2 Appendice Tecnica Rev 1 0 26 02 01...
Page 49: ...VJ1000HP Telemetry Cable 1 2 Appendice Tecnica Rev 1 1 26 02 01...
Page 51: ...VJ1000HP Power Supply 1 4 Appendice Tecnica Rev 1 0 25 05 02...
Page 52: ...VJ1000HP 2 4 Power Supply Technical Appendix Rev 1 1 20 05 02...
Page 55: ...VJ1000HP H T Rectifier Board 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 56: ...VJ1000HP 2 4 H T Rectifier Board Technical Appendix Rev 1 0 26 02 01...
Page 59: ...VJ1000HP R F Block 1 ph 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 68: ...VJ1000HP 2 4 Grid Plate Meter B Technical Appendix Rev 1 0 26 02 01...
Page 72: ...VJ1000HP 2 4 Low Pass Filter Technical Appendix Rev 1 0 26 02 01...
Page 75: ...VJ1000HP Input Matching Circuit 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 76: ...VJ1000HP 2 4 Input Matching Circuit Technical Appendix Rev 1 0 26 02 01...
Page 80: ...VJ1000HP 2 4 Directional Coupler Technical Appendix Rev 1 0 26 02 01...
Page 83: ...VJ1000HP Telemetry Card opt 1 4 Appendice Tecnica Rev 1 0 26 02 01...