![background image](http://html1.mh-extra.com/html/r-v-r-elettronica/vj1000hp/vj1000hp_user-manual_3117269019.webp)
VJ1000HP
13 / 40
USER MANUAL
Rev. 4.0 - 26/02/01
FRONT PANEL’S VIEW DESCRIPTION (FIG. 1)
1
OUTPUT POWER
Analog meter for the measurement of direct
and reflected output power
2
DIR/REF
Switch for the selection of direct or reflected
power measurment
3
CURRENTS
Analog meter for the measurement of anode
and grid currents
4
GRID/PLATE
Switch for the selection of grid or anode
current measurement
5
TUNING
Motorized tuning switch
6
LED "-" (87,5)
LED to indicate that tuning has reached end
of range at 87.5 MHZ. OFF signifies end of
range
7
PLATE
Anode tuning swich
8
LED "+" (108)
LED to indicate that tuning has reached end
of range at 108 MHZ. OFF signifies end of
range
9
LOAD
Load matching switch
10
V.S.W.R.
Indicator shwing excess V.S.W.R.
11
PRESS.
Indicator showing insufficent fan pressure
12
I.G.
Alarm indicator for excess grid current
13
H.T.
Indicator showing high voltage active
14
ON
Power indicator
15
ST.BY.
Standby switch
16
POWER
Power ON/OFF switch
17
PANNELLO H.T.
Internal access to RF chamber
18
RESTART
Alarm reset (only in the version with telemtry
option)
19
ALARMS CARD ON
Alarms card on (only in the version with
telemetry option)
Summary of Contents for VJ1000HP
Page 1: ...Prodotto da Italia VJ1000HP User Manual...
Page 4: ...This page intentionally left blank...
Page 20: ...VJ1000HP 14 40 USER MANUAL Rev 4 0 26 02 01 FIG 1...
Page 22: ...VJ1000HP 16 40 USER MANUAL Rev 4 0 26 02 01 FIG 2...
Page 24: ...VJ1000HP 18 40 USER MANUAL Rev 4 0 26 02 01 PHOTO 1 3 1 2 5 7 11 9 4 6 8 12 10...
Page 26: ...VJ1000HP 20 40 USER MANUAL Rev 4 0 26 02 01 PHOTO 2 1 2 3 4 5 6...
Page 28: ...VJ1000HP 22 40 USER MANUAL Rev 4 0 26 02 01 PHOTO 3 7 2 3 6 5 4 1...
Page 40: ...VJ1000HP 34 40 USER MANUAL Rev 4 0 26 02 01 SETUP 1 FIG 3...
Page 41: ...VJ1000HP 35 40 USER MANUAL Rev 4 0 26 02 01 SETUP 2 FIG 4...
Page 42: ...VJ1000HP 36 40 USER MANUAL Rev 4 0 26 02 01 SETUP 3 FIG 5...
Page 46: ...VJ1000HP 40 40 USER MANUAL Rev 4 0 26 02 01 This page intentionally left blank...
Page 47: ...VJ1000HP Flat Cable 1 2 Appendice Tecnica Rev 1 0 26 02 01...
Page 49: ...VJ1000HP Telemetry Cable 1 2 Appendice Tecnica Rev 1 1 26 02 01...
Page 51: ...VJ1000HP Power Supply 1 4 Appendice Tecnica Rev 1 0 25 05 02...
Page 52: ...VJ1000HP 2 4 Power Supply Technical Appendix Rev 1 1 20 05 02...
Page 55: ...VJ1000HP H T Rectifier Board 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 56: ...VJ1000HP 2 4 H T Rectifier Board Technical Appendix Rev 1 0 26 02 01...
Page 59: ...VJ1000HP R F Block 1 ph 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 68: ...VJ1000HP 2 4 Grid Plate Meter B Technical Appendix Rev 1 0 26 02 01...
Page 72: ...VJ1000HP 2 4 Low Pass Filter Technical Appendix Rev 1 0 26 02 01...
Page 75: ...VJ1000HP Input Matching Circuit 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 76: ...VJ1000HP 2 4 Input Matching Circuit Technical Appendix Rev 1 0 26 02 01...
Page 80: ...VJ1000HP 2 4 Directional Coupler Technical Appendix Rev 1 0 26 02 01...
Page 83: ...VJ1000HP Telemetry Card opt 1 4 Appendice Tecnica Rev 1 0 26 02 01...