VJ1000HP
30 / 40
USER MANUAL
Rev. 4.0 - 26/02/01
8. Calibration Procedure
N.B. THE FOLLOWING PROCEDURE SHOULD ONLY BE CARRIED OUT BY QUALIFIED
PERSONNEL USING THE CORRECT TOOLS AND EQUIPMENT. UNQUALIFIED OR
INEXPERIENCED PERSONNEL NOT USING THE CORRECT TOOLS AND
EQUIPMENT CAN EASILY CAUSE DAMAGE TO THE UNIT WHICH WILL
IMMEDIATELY INVALIDATE THE GUARANTEE.
8.1
Frequency Changes
To change the operating frequency of a tube amplifier the following procedure is required:
1)
Select the desired frequency on the exciter.
2)
Reduce exciter power to minimum power.
3)
Connect the line supply (220V ±5%) to the unit.
4)
Switch the POWER switch to ON, the corresponding indicator will show the presence of
the line supply in the unit and, at the same time the cooling fan will start.
Normally the PRESS. indicator will stay on for a few seconds before the fan has created
sufficient air flow.
After 2/3 minutes of warming up, the HT indicator will light up; simultaneously the
characteristic noise of the power solenoid will be heard indicating that the anode supply
is active.
The driver will also be active. The unit without excitation will absorb about 30 mA of
anode current.
5)
Switch the OUTPUT POWER switch to DIR and the CURRENTS switch to PLATE.
6)
Adjust the exciter power control to obtain an anode current of 200mA.
7)
Using the TUNING switch, activate the tuning motors so that both green leds next to the
PLATE control light up.
Holding the TUNING switch down, use the PLATE "+" or "-" control (the unit is factory
set to a frequency of 98 MHz) to tune the plate circuit.
"+" indicates an increase in frequency and "-", a reduction in frequency.
If one of the leds switches off, this indicates that the end of the frequency range has
been reached and that no more adjustment is available in that direction.
The OUTPUT POWER meter can be used to tune the plate circuit; maximum meter
reading (maximum output power) corresponding to correct tuning.
8)
The LOAD tuning procedure follows in a similar fashion: holding down the TUNING
switch, adjust the LOAD control for maximum output power.
Summary of Contents for VJ1000HP
Page 1: ...Prodotto da Italia VJ1000HP User Manual...
Page 4: ...This page intentionally left blank...
Page 20: ...VJ1000HP 14 40 USER MANUAL Rev 4 0 26 02 01 FIG 1...
Page 22: ...VJ1000HP 16 40 USER MANUAL Rev 4 0 26 02 01 FIG 2...
Page 24: ...VJ1000HP 18 40 USER MANUAL Rev 4 0 26 02 01 PHOTO 1 3 1 2 5 7 11 9 4 6 8 12 10...
Page 26: ...VJ1000HP 20 40 USER MANUAL Rev 4 0 26 02 01 PHOTO 2 1 2 3 4 5 6...
Page 28: ...VJ1000HP 22 40 USER MANUAL Rev 4 0 26 02 01 PHOTO 3 7 2 3 6 5 4 1...
Page 40: ...VJ1000HP 34 40 USER MANUAL Rev 4 0 26 02 01 SETUP 1 FIG 3...
Page 41: ...VJ1000HP 35 40 USER MANUAL Rev 4 0 26 02 01 SETUP 2 FIG 4...
Page 42: ...VJ1000HP 36 40 USER MANUAL Rev 4 0 26 02 01 SETUP 3 FIG 5...
Page 46: ...VJ1000HP 40 40 USER MANUAL Rev 4 0 26 02 01 This page intentionally left blank...
Page 47: ...VJ1000HP Flat Cable 1 2 Appendice Tecnica Rev 1 0 26 02 01...
Page 49: ...VJ1000HP Telemetry Cable 1 2 Appendice Tecnica Rev 1 1 26 02 01...
Page 51: ...VJ1000HP Power Supply 1 4 Appendice Tecnica Rev 1 0 25 05 02...
Page 52: ...VJ1000HP 2 4 Power Supply Technical Appendix Rev 1 1 20 05 02...
Page 55: ...VJ1000HP H T Rectifier Board 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 56: ...VJ1000HP 2 4 H T Rectifier Board Technical Appendix Rev 1 0 26 02 01...
Page 59: ...VJ1000HP R F Block 1 ph 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 68: ...VJ1000HP 2 4 Grid Plate Meter B Technical Appendix Rev 1 0 26 02 01...
Page 72: ...VJ1000HP 2 4 Low Pass Filter Technical Appendix Rev 1 0 26 02 01...
Page 75: ...VJ1000HP Input Matching Circuit 1 4 Appendice Tecnica Rev 1 0 26 02 01...
Page 76: ...VJ1000HP 2 4 Input Matching Circuit Technical Appendix Rev 1 0 26 02 01...
Page 80: ...VJ1000HP 2 4 Directional Coupler Technical Appendix Rev 1 0 26 02 01...
Page 83: ...VJ1000HP Telemetry Card opt 1 4 Appendice Tecnica Rev 1 0 26 02 01...