5.4.2 Power menu (Pwr)
This screen holds all readings related to equipment output power:
Menu 5
Fwd
Forward power reading.
Rfl
Reflected power reading.
Note that these are readings, rather than settings, and cannot be edited (note
the empty triangle). To change power setting, go to the
default menu
as outlined
earlier.
5.4.3 Power Amplifier (P.A) Menu
This screen is made up of four lines that can be scrolled using the
and
buttons and shows the readings relating to final power stage:
Menu 6
Note that these are readings, rather than settings, and cannot be edited (note the
empty arrow).
VPA
Voltage supplied by amplifier module.
IPA
Current draw of amplifier module.
Eff
Efficiency based on ratio of forward power to amplifier module power,
in percent ( FWD PWR/(Vpa x Ipa) % ).
Tmp
Equipment internal temperature reading.
Bat
Voltage supplied by external battery.
NOTE: it is normal that with mains power supplied in
Bat
there is a voltage of about
29 V, this is synonymous of the proper functioning of the mains power supply.