 1. 

Preliminary 

Instructions

• General foreword

The equipment in object is to considering for uses, 
installation and maintenance from “trained” or “qualifi ed” 
staff, they conscious of the risks connected to operate 
on electronic and electrical circuits electrical.   
The “trained” definition means staff with technical 
knowledge about the use of the equipment and with 
responsibility regarding the own safety and the other 
not qualified staff safety place under his directed 
surveillance in case of works on the equipment.   
The “qualifi ed”  defi nition means staff with instruction and 
experience about the use of the equipment and with 
responsibility regarding the own safety and the other not 
qualifi ed staff safety place under his directed surveillance 
in case of works on the equipment. 

 WARNING: The machine can be equipped with 

an ON/OFF switch which could not remove completely 
voltages inside the machine. It is necessary to 
have disconnected the feeding cord, or to have 
switched off the control panel, before to execute 
technical operations, making sure himself that the 
safety connection to ground is connected. 
The technical interventions that expect the equipment 
inspection with circuits under voltage must be carry out 
from trained and  

qualifi ed staff in presence of a 

second trained person that it is ready to intervene 
removing voltage in case of need.

R.V.R. Elettronica SpA doesn’t assume responsibility for 
injury or damage resulting from improper procedures or 
practices by untrained/unqualifi ed personnel in the handling 
of this unit.

 WARNING: The equipment is not water resistant 

and an infiltration could seriously compromise 
its correct operation.  In order to prevent fires or 
electric shocks, do not expose the equipment to rain, 
infi ltrations or humidity.

Please observe all local codes and fi re protection standards 
during installation and use of this unit.

 WARNING: The equipment has to its inside 

exposed parts to risk of electric shock, always 
disconnect power before opening covers or removing 
any part of this unit.

Fissures and holes are supplied for the ventilation in order 
to assure a reliable effi cacy of the product that for protect 
itself from excessive heating, these fi ssures do not have 
to be obstructed or to be covered. The fi ssures doesn’t be 
obstructed in no case.  The product must not be incorporated 
in a rack, unless it is supplied with a suitable ventilation or 
that the manufacturer’s instructions are been followed.

 WIRING: This equipment can irradiate radio 

frequency energyand if it’s not installed following 
the instructions contained in the manual and local 
regulations it could generate interferences in radio 
communications.

 WIRING: This device has a connection to ground 

on the power cord and on the chassis.  Check that they 
are correctly connected.

Operate with this device in a residential ambient can cause 
radio disturbs; in this case, it can be demanded to the user 
to take adequate measures.

Specifi cations and informations contained in this manual  
are furnished for information only, and are subject to change 
at any time without notice, and should not be construed 
as a commitment by R.V.R. Elettronica SpA
The R.V.R. Elettronica SpA assumes no responsability or 
liability for any errors or inaccuracies that may appear in 
this manual, including the products and software described 
in it;and it reserves the right to modify the design and/or 
the technical specifi cations of the product and this manual 
without notice.

• Warning regarding the use designated and the use 
limitations of the product.

T h i s   p r o d u c t   i s   a n   t r a n s m i t t e r   r a d i o   i n d i c a t e d 
for the audio broadcasting service in frequency 
modulation. It uses working frequencies that are not 
harmonized in the states of designated user. 
The user of this product must obtain from the Authority 
for spectrum management in the state of designated 
user the appropriate authorization to use the radio 
spectrum, before putting in exercise this equipment. 
The working frequency, the transmitter power, let alone 
other specifi cations of the transmission system are subject 
to limitation and defi nited in the authorization obtained.

 2. 

Warranty

R.V.R. Electronics S.P.A. guarantees absence of 
manufacturing defect and the good operation for the 
products, within the provided terms and conditions.

Please read the terms carefully, because the purchase of 
the product or acceptance of order confi rmation, constitutes 
acceptance of the terms and conditions.

For the last legal terms and conditions, please visit our web 
site (WWW.RVR.IT) wich may also be changed, removed 
or updated for any reason without prior notice.

Warranty will be void in cases of opened products, physical 
damage, misuse, modification, repair by unauthorised 
persons, carelessness and using the product for other 
purpose than its intended use.

In case of defect, proceed like described in the following:

Contact the dealer or distributor where you purchased 
the unit. Describe the problem and, so that a possible 
easy solution can be detected.

Dealers and Distributors are supplied with all the information 
about problems that may occur and usually they can repair 
the unit quicker than what the manufacturer could do. Very 
often installing errors are discovered by dealers.

If your dealer cannot help you, contact  R.V.R. Elettronica 
and explain the problem. If it is decided to return the 
unit to the factory,  R.V.R. Elettronica  will mail you a 
regular authorization with all the necessary instructions 
to send back the goods;

When you receive the authorization, you can return the 
unit. Pack it carefully for the shipment, preferably using 
the original packing and seal the package perfectly. 
The customer always assumes the risks of loss (i.e., 

IMPORTANT

The symbol of lightning inside a triangle placed on the product, evidences the operations for 
which is necessary gave it full attention to avoid risk of electric shocks. 

The symbol of exclamation mark inside a triangle placed on the product, informs the user 
about the presence of instructions inside the manual that accompanies the equipment, im-
portant for the effi cacy and the maintenance (repairs).

Summary of Contents for TELINK-SNMP1

Page 1: ...TELINK SNMP1 User Manual Volume 1 Manufactured by Italy...

Page 2: ...may be reproduced memorized or transmitted in any form or by any means electronic or mechanic including photocopying recording or by any informa tion storage and retrieval system without written perm...

Page 3: ...cription 3 5 Installation and configuration procedure 5 5 1 Preparation 5 5 2 First Power On and Set Up 6 5 3 Management Firmware 8 6 External Description 14 6 1 Front Panel 14 6 2 Rear Panel 15 6 3 C...

Page 4: ...TELINK SNMP1 ii User Manual Rev 1 0 13 03 09 This page was intentionally left blank...

Page 5: ...e measures Specifications and informations contained in this manual are furnished for information only and are subject to change at any time without notice and should not be construed as a commitment...

Page 6: ...bsent begin artificial circulation Figure 4 depressing sternum Figure 5 Figure 3 Figure 4 Figure 5 In case of only one rescuer 15 compressions alternated to two breaths If there are two rescuers the r...

Page 7: ...ted through male and female connectors or through flat cables terminated by connectors This design facilitates maintenance and module replacement The TELINK SNMP1 is an interface endowed with a microc...

Page 8: ...equipped with watchdog hardware to reset the equipment automatically in case of abnormal stop of processor or in case of lowering below the threshold about power supply voltage TELINK SNMP1 has a sim...

Page 9: ...tions for additional details IMPORTANT when configuring and testing the transmitter in which this telemetry unit is integrated be sure to have the Final Test Table supplied with the equipment ready at...

Page 10: ...to ensure equipment correct operation 3 Connect the network cable to the relevant MAINS VOLTAGE connector on TELINK SNMP1 interface 5 2 First Power On and Set Up Perform this procedure upon first pow...

Page 11: ...ion of the equipment connected to the network Measurements and commands are described by a MIB Management Information Base which is a list of OID Object Identifier Each OID is a variable that can be w...

Page 12: ...data in the Main card The Main card then sends the data to the ANTLAN SNMP card for formatting analysis which finally export the data obtained as SNMP In the following you can find the list of typica...

Page 13: ...d in this release For each analog measurement can be set The maximum value MAX is the fixed point beyond which is sent a TRAP The minimum value MIN is the fixed point below which is sent a TRAP The hy...

Page 14: ...is no alarm or the maximum value MAX alarm is active the minimum value MIN alarm is set To exit the MIN alarm condition the value should be equal to the MIN value plus the value of hysteresis Note the...

Page 15: ...ng analysis which finally export the data obtained as SNMP Menu 5 Each input is associated to the tree of alarms settings Similarly to measurements described in the previous chapter the structure for...

Page 16: ...the menus above the operation mode is adjustable 5 3 3 TRAP sending The telemetry system is capable to sending TRAP up to five different addresses Different addresses can be set using the OID in major...

Page 17: ...nd Usually the commands are one shot toggle In other words if the transmitter is turn ON value 2 to set transmitter on 10ksd the next command is a turn OFF value 2 set transmitter off 10ksd and not a...

Page 18: ...n This section describes the components found on the front and rear panel of TELINK SNMP1 6 1 Front Panel Figure 6 1 1 DC OUT Green LED Lit on when the power supply works and cards feed correctly 2 MA...

Page 19: ...8 DIPSWITCH 1 Dip switch to regulate the TELINK card for configuration read the TELINK user manual 9 DIPSWITCH 2 Dip switch to regulate the TELINK card for configuration read the TELINK user manual 1...

Page 20: ...ctor Description 6 3 1 RS232 Type DB9 Male 1 N C 2 RxD 3 TxD 4 N C 5 GND 6 N C 7 N C 8 N C 9 N C 6 3 2 SERVICE Type DB9 female 1 DCD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI 6 3 3 PROG Type RJ45...

Page 21: ...17 24 User Manual Rev 1 0 13 03 09 TELINK SNMP1 6 3 4 ETHERNET Type RJ45 female 1 TX 2 TX 3 RX 4 N C 5 N C 6 RX 7 N C 8 N C...

Page 22: ...Dimensions W x H x D 483 x 44 x 300 mm Weigh 4 kg Environmental working temperature 10 to 50 C Cooling type Forced with internal fans Analog Digital Analog Relay RS232 Yes RS485 Yes IIC BUS RJ 45 LAN...

Page 23: ...nd layout of the cards are given in the Technical Appendix Vol 2 8 1 Power Supply The power supply on this amplifier provides to RF power module a DC voltage of 24 V with a maximum current of 2 1 A It...

Page 24: ...s i e from internet radio_rvr_spa it instead xxx xxx xxx xxx More information about use configuration of Dip Switches on rear panel and configuration of this card are given in the TELINK user manual w...

Page 25: ...e back of the card visible from rear panel are located 2 synoptics LED panels Information is available below SYNOPTIC 1 note 14 fig 6 2 RX RS232 Green Led Blinks during data reception in RS232 standar...

Page 26: ...t on indentifies malfunctions on hardware Green Led Blink identifies the proper functioning of watchdog on card SNMP Green Led Blink during a SNMP interrogation ended successfully SYNOPTIC 3 note 17 f...

Page 27: ...ules linked to each other through connectors so as to make maintenance and any required module replacement easier 9 1 Upper View The figure below shows the equipment upper view with the various compon...

Page 28: ...24 24 User Manual Rev 1 0 13 03 09 TELINK SNMP1 This page was intentionally left blank...

Reviews: