SCM6/1
ELETTRONICA
27
/ 40
User Manual
Rev. 2.0 - 29/11/22
If during any of the above mentioned delays, the RF power of the current transmitter
comes back, the process exits with the value “Power fault not validated”.
TXi Inhibit
present?
Start timer
TXi “Inhibit”
(360” config.)
TXi Still
PG Fault?
Timer expired?
Start timer
TXi “before”
(5” config.)
no
HT present?
“Power Fault TXi”
Validated
Timer Recycl
TXi=0
Start timer
Recycl. TXi (20”)
Timer expired?
TXi Still
PG Fault?
TXi Inhibit
present?
TXi Inhibit
present?
TXi Still
PG Fault?
Timer expired?
Power Fault
not validated
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
no
no
no
no
no
yes
yes
no
D
E
Figure 6-7: Power fault validation
6.2.4 Permutation
The permutation process (Figure 4-8 )can actually assume two forms, depending
on the kind of permutation to be done, that is Position 1 to Position 2 or vice versa,
as determined by the “priority management” process.