9.3.1 How to replace a malfunctioning blower
• Unscrew all screws
A
on the front panel of
PJ5000U-K
.
A
• Disconnect the power fan connector
B
, unscrewing the two slotted screws
present.
C
B
• Unscrew the four screws
C
and remove the malfunctioning blower.
• Insert the new blower (mod.
9GV0824P1G03 Sanyo-Denki
) and retighten the
four fixing screws
C
.
• Reconnect the connector in the position
B
and secure it with two screws.
• Replace the front cover and screw all the screws into the position
A
.
9.4 Module substitutions
Only authorized and qualified technical personnel must be proceed with the
replacement of the component parts in the relevant device.
9.4.1 How to replace the RF module
• Open the bottom cover of
PJ5000U-K
by unscrewing all the screws.
• Identify the RF module to be replaced by a visual inspection, a check on the
voltage and/or the verification of a possible broken fuse.