WARNING: Electric shock hazard! Never handle the RF output connector
when the equipment is powered on and no load is connected. Injury or death
may result.
Ensure that the distribution board of the transmitter is set to “OFF”.
5.1.3 Device power supply connections
Provide for the following (applicable to operating tests and putting into service):
√
Single phase mains power supply (P+N) 230 VAC (-15% / +10%) or three phase
mains power supply (3P+N) 400 VAC (-15% / +10%) , both with adequate earth
connection.
√
FM exciter with adjustable output power up to 50W (minimum), as the RVR
Elettronica PTX60LCD/S.
√
For operating tests only: dummy load with 50 Ohm impedance and adequate
capacity (5000W as a minimum).
Nota:
to ensure the safety of the operators, carry out the wiring according to the
laws and regulations in force in the country where this equipment is installed.
Check that the
POWER
switch on the front of
PJ5000U-K
is in the “
OFF
”
position..
An ILME model KKCNTCQF04/2 (CQF04/2) multipole socket is supplied with the
amplifier to power the machine. The socket must be connected to the multipole
cable that will be wired to the mains switchboard.
WARNING: to avoid any risk of shock make absolutely sure that the power
supply cable is NOT powered when the multipole socket is connected to the
cable itself..
Connect the multipole socket to the power supply cable as described below and
refer to figure 5.1: