To edit an item, highlight the appropriate line using the UP and DOWN buttons and
then press and hold the
ENTER
button until the command is accepted. This way,
Pwr setting is toggled between On and Off and Mod setting is toggled between
“x1” and “x10”. To edit the Power Good rate, simply select item “PgD” and edit its
value using buttons and ; finally, press
ENTER
to confirm.
Menu 4
Pwr
Enables (ON) or disables (OFF) amplifier power output.
Loc
Modifies machine operation. In the LOCAL mode, the machine can read
and modify its operating parameters through the navigation keys and the
management firmware, whereas all other sources are locked out. In the
REMOTE mode, the machine can only read its operating parameters;
parameters are modified based on the commands received from other
connected telemetry systems.
Pg1
Modifies Power Good (forward power) threshold. The Power Good rate
is a percent of machine rated power (5000W for
PJ5000U-K
), not of
forward output power. This means that this threshold set at 50% will
give 2500 W regardless of set power level. The Power Good feature
enables output power control and reporting. When output power drops
below set Power Good threshold, the equipment changes the state of
pin [9] of the DB25 “Remote” connector located on the rear panel..
Pg2
Like
Pg1
, modifies a second Power Good threshold for forward
power. When output power drops below set Power Good threshold,
the equipment changes the state of pin [22] of the DB25 “Remote”
connector located on the rear panel..
Pg3
Like
Pg1
, modifies Power Good threshold for reflected power. When
output power drops below set Power Good threshold, the equipment
changes the state of pin [18] of the DB25 “Remote” connector located
on the rear panel..
Pg4
Like
Pg1
, modifies a second Power Good threshold for reflected
power..