TEX30/50/100/150/300LCD
ELETTRONICA
11
/ 32
User Manual
Rev. 1.0 - 29/11/12
√
For operating tests only: dummy load with 50 Ohm impedance and adequate
capacity (30W for
TEX30LCD,
50W for
TEX50LCD,
100W for
TEX100LCD,
150W for
TEX150LCD
or
300W for
TEX300LCD
as a minimum).
√
Connection cable kit including:
• Mains power cable
• Coaxial cable with BNC connectors for interlock signal connection
• RF cable for output to load / antenna (50 Ohm coaxial cable with N-type
connector)
• Audio cables between transmitter and audio sources.
5.1.2 Connections
Connect the RF output of the transmitter to the antenna cable or a dummy load
capable of dissipating amplifier output power. To begin with, set exciter to minimum
output power and switch it off.
Connect the transmitter INTERLOCK IN input to the matching INTERLOCK OUT
output fitted on R.V.R. Elettronica equipment to act as hybrid couplers. If your
equipment is a different brand, identify an equivalent output.
Figure 5.2:
connections with amplifier
WARNING: Electric shock hazard! Never handle the RF output connector
when the equipment is powered on and no load is connected. Injury or death
may result.
Ensure that the POWER switch on the front panel of
TEX30/50/100/150/300LCD
is set to “
OFF
”.