Make sure fuse or circuit breaker is correct rating for machine. Using fuses or circuit breakers smaller
than recommended will result in 'nuisance' shut off from welder inrush currents even if welding at low
amperages.
Failure to follow these instructions can cause immediate failure within the welder and void machines
warranty.
Turn the input power OFF at the mains switch & fuse box before working on this equipment.
Have a qualified electrician install & service this equipment.
Allow machine to sit for 5 minutes minimum to allow the power capacitors to discharge before
working inside this equipment. Do not touch electrically live parts
The TIG200PDC Inverter Tig Welder requires a 240V 50/60Hz 32amp fused supply.
It comes with a 3 metre mains cable attached.
Connect wires according to national coding.
Brown wire - Live
Blue wire - Neutral
Green/Yellow Wire - Earth (Ground)
Connecting to an Engine Driven Generator
I
f connecting this machine to an engine driven generator please ensure
the following
Minimum Generator KVA Output - 7.5 KVA
continuous Generator to be fitted with AVR (automatic voltage regulation)
DO NOT USE ON A GENERATOR WITHOUT AVR
Connecting to a generator without the above minimum requirements will
invalidate your warranty.
7
Summary of Contents for TIG200PDC
Page 2: ...2...
Page 19: ...Wiring diagram 19...