7
than recommended will result in ‘nuisance’ shut off from welder inrush currents even if cutting at low
amperages.
Failure to follow these instructions can cause immediate failure within the welder and void machines
warranty.
Turn the input power OFF at the mains switch & fuse box before working on this equipment.
Have a qualified electrician install & service this equipment.
Allow machine to sit for 5 minutes minimum to allow the power capacitors to discharge before working
inside this equipment. Do not touch electrically live parts
The Plasma 30DV Plasma Cutters require a 110 or 240V 50/60Hz 1-Phase supply. It requires an 13A
supply for 240V and 32A supply for 110V operation. It comes with a mains cable attached.
The P30DV features auto input voltage sensing, simply connect to either 110V or 240V supply and the
machine will auto adjust itself. No switches or internal changes required.
Connect wires according to national coding.
Brown wire – Live
Blue wire – Neutral
Green/Yellow Wire – Earth (Ground)
Connecting to an Engine Driven Generator
If connecting this Plasma Cutter to an engine driven generator please ensure the
following
Minimum Generator KVA Output – 5KVA continuous
Generator to be fitted with AVR (automatic voltage regulation)
DO NOT USE ON A GENERATOR WITHOUT AVR
Connecting to a generator without the above minimum requirements will in-
validate your warranty.