f)  Re-assemble the quartz sleeve with spring in the UV chamber allowing the sleeve to protrude an equal 

distance from both ends of the UV chamber.

g) Wet the o-rings and slide onto each end of the quartz sleeve and reassemble the gland nuts (hand tight is 

sufficient).

h) Re-tighten all connections, turn on water and check for leaks.
I)  Re-install the UV lamp and lamp connector as per prior instructions.
j)  Reconnect system to power source.

Note:

If the system is put on a temporary by-pass or if it becomes contaminated after the disinfection system, it

will be necessary to shock the system with household bleach for a full 20 minutes before resuming use of the
water.

C.  UV SENSOR REPLACEMENT AND/OR CLEANING (Applies to S12Q-GOLD & S24Q-GOLD systems only):

1.

Mineral deposits and sediment may accumulate on the sensor probe decreasing the UV detection rate. Good 

maintenance of filtration equipment will reduce the accumulation of residues. If necessary, remove the sensor 
probe after a few months and proceed with cleaning process. Repeat the process as often as necessary to keep the 
sensor probe clean.

2.

Disconnect the UV sensor from the rear of the disinfection system and drain the reactor chamber as per prior 

instructions. Remove the sensor probe by unscrewing retaining nut. Do not attempt to disassemble the sensor 
probe itself. Any tampering with the internal components of the sensor probe will result in voiding the warranty. 
The probe face should be cleaned with a commercially available scale remover (CLR, Lime-Away, etc.) and a lint 
free cloth. Carefully reassemble the sensor probe into the sensor boss by first inserting the sensor o-ring and then 
the sensor itself. Screw the sensor retaining nut and tighten to achieve a water tight seal. DO NOT OVER 
TIGHTEN. Attach the sensor cable to the connector on the rear of the UV disinfection system.

LAMP FAILURE SYSTEM  (Standard on S12Q, S24Q, S40Q)

The audible alarm and indicator lights on the systems continuously monitor the lamp operation.  If the lamp does not
start at any time, the indicator light will not glow and the audible alarm will sound.  This alarm indicates that the UV
lamp is no longer operating and must be corrected.  Please refer to Troubleshooting Guide for corrective procedures.

ULTRAVIOLET MONITORING SYSTEM  (Standard on GOLD models)

The ultraviolet sensor system features a complete warning system for continuous water protection by constantly sensing
the UV INTENSITY at the inside surface of the cell.  The system features a single LED indicator light, which will show
three distinct colours, 

GREEN, YELLOW, 

and 

RED

.  When the UV output level changes, the warning system will operate

in the following manner:

GREEN

indicates that the UV intensity is satisfactory and the unit is in good working order.

YELLOW

indicates that the UV intensity is reduced, which could be due to any of the following factors :

• The lamp is losing strength and will soon need to be replaced.
•  The quartz sleeve and/or the sensor probe have become dirty.   Mineral deposits or sediment in the 

water that was not detected during the original water analysis may be the cause for this.  The quartz 
sleeve and sensor probe should be cleaned and the system re-installed to determine if dirt was the 
cause of the yellow light.  If the LED light switches to yellow soon after the unit is installed or  the 
lamp has been replaced, dirt accumulation is most likely the cause.

•  Intermittent voltage drop in the household power supply reducing the lamp output. The lamp will 

return to normal when the power is restored to full voltage. Note : The monitoring system will not 
operate during power failures.

FLASHING RED

indicates that system cut-off is imminent where solenoid is fitted. Immediate action is required.

RED

indicates that the unit needs immediate attention, the audible alarm will automatically sound when the LED

monitor light switches to red. If the lamp has been in service for a year or more it should be replaced. The quartz
sleeve and/or sensor probe may require cleaning.  The alarm will continue until the sensor detects adequate UV
intensity. When a lamp is replaced it is recommended to clean the quartz sleeve and sensor probe prior to returning
the system to service.

SOLENOID CONTACTS  (Standard on S12Q-GOLD & S24Q-GOLD models)

GOLD units come equipped with the capability of adding an optional solenoid valve available from your dealer. This 
normally closed solenoid will work in conjunction with the UV monitoring system physically stopping the water flow if
the UV sensor determines that the water is not being adequately treated. The LED indicator will be red and the audible
alarm will be sounding. Water will only be allowed to flow when the UV disinfection system senses that the quality of 
the water has returned to a safe state.  Ideally, the solenoid valve should be installed on the influent side of the 
disinfection system. To install, disconnect power supply prior to opening disinfection system cover. Plumb solenoid valve 

W

ARNING

S

YSTEMS

:

Summary of Contents for Sterilight S12Q

Page 1: ...er s Manual P N 520022 October 2004 425 Clair Road West P O Box 1719 Guelph ON N1H 7X4 Canada t 519 763 1032 f 519 763 5069 t f 1 800 265 7246 e water r can com i www r can com S12Q S12Q GOLD S24Q S24...

Page 2: ...Chemistry Page 2 Installing Your Disinfection System Page 2 Operating Maintenance Instructions Page 3 4 Warning Systems Page 4 5 Warranty Page 5 Troubleshooting Page 6 8 Parts Page 9 Specifications P...

Page 3: ...temperatures below freezing Do not store this disinfection system where it will be exposed to the weather Do not store this disinfection system where it will be exposed to temperatures below freezing...

Page 4: ...nnections are made slowly turn on the water supply and check for leaks The most likely cause for leaks is from the o ring seal In case of a leak shut water off drain cell remove the retainer nut wipe...

Page 5: ...The connector is keyed and will only allow correct installation in one position Ensure the connector is fully seated onto the UV lamp 3 Once the lamp is fully seated on the connector slide the connect...

Page 6: ...tection by constantly sensing the UV INTENSITY at the inside surface of the cell The system features a single LED indicator light which will show three distinct colours GREEN YELLOW and RED When the U...

Page 7: ...cable for remote monitoring of the audible and visual signals provided by the UV monitoring mechanism THIS ADVANCED WARNING SYSTEM HAS BEEN INSTALLED TO PROVIDE YOU WITH THE OPTIMUM PRECAUTIONS TO EN...

Page 8: ...the disinfection system it is imperative that the effluent water stream be shocked with chlorine after the water leaves the disinfection system the disinfection system must have a bacteria free distr...

Page 9: ...ALARM UV LAMP ON ON OFF ON Correct operating conditions unit is functioning properly OFF OFF OFF OFF The unit is not plugged into the electrical outlet Plug unit into receptacle and ensure proper powe...

Page 10: ...acturer replacement Always Wet Sensor Lens prior to inserting sensor check water quality see page 2 for water parameters RED ON ON UV Sensor has not detected enough UV Intensity to adequately protect...

Page 11: ...IRCUIT BOARD for 115V unit CB 2440A 2 CIRCUIT BOARD for 230V unit RN 001 ALUMINUM RETAINING NUT CP 1240 CIRCUIT BOARD COVER CS 001 Q CORD SET 115V CS EU Q EUROPEAN SCHUKO CORD SET 230V DP750 RETAINING...

Page 12: ...ER CONSUMPTION 42 W 42 W 95 W 95 W 190 W TOTAL LAMP WATTS 39 W 39 W 78 W 78 W 156 W MAXIMUM OPERATING PRESSURE 8 62 bar 125 psi 8 62 bar 125 psi 8 62 bar 125 psi 8 62 bar 125 psi 8 62 bar 125 psi AMBI...

Page 13: ...N 520022 octobre 2004 425 chemin Clair ouest C P 1719 Guelph ON N1H 7X4 Canada t l 519 763 1032 s f 1 800 265 7246 t l c 519 763 5069 courriel water r can com site Internet www r can com EPA 57987 CN...

Page 14: ...miques de l eau Page 2 L installation de votre syst me de d sinfection Page 2 Directives d utilisation et d entretien Page 3 4 Syst mes d advertissement Page 4 5 Garantie Page 5 Diagnostic Page 6 8 Co...

Page 15: ...toujours l alimentation d eau d un syst me de d sinfection et sa prise lectrique avant de commencer son nettoyage ou son entretien Ne tirez jamais sur le cordon pour le d brancher de la prise murale...

Page 16: ...ntenue dans le compartiment se r chauffe s il n y a pas d coulement Pour rem dier cette situation laisser couler pendant une minute un robinet d eau froide de la maison Vous vacuerez ainsi l eau chaud...

Page 17: ...est bien cal sur la lampe UV 3 D s que la lampe est bien fix e au connecteur glissez le sur l crou de retenue en aluminium Assurez vous que la bague m tallique de retenue du connecteur n emp che pas c...

Page 18: ...OUR VOUS PROCURER UNE PROTECTION OPTIMALE CONTRE LA CONTAMINATION MICROBIOLOGIQUE DE VOTRE EAU NE N GLIGEZ PAS LES AVERTISSEMENTS LUMINEUX LA MEILLEURE FA ON DE V RIFIER LE BON FONCTIONNEMENT DE VOTRE...

Page 19: ...otre d taillant Cette vanne sol no de qui est normalement ferm fonctionne en parall le avec le syst me de contr le UV pour arr ter l coulement de l eau si le capteur UV d tecte qu elle n est pas trait...

Page 20: ...d utilisation de cet appareil Contamination apr s le syst me de d sinfection Il est imp ratif que l eau effluente re oive un traitement de choc au chlore apr s que l eau quitte le syst me de d sinfec...

Page 21: ...M E TEINTE ALLUM E Conditions de fonctionnement correctes l appareil fonctionne correctement TEINTE TEINTE TEINTE TEINTE L indicateur est DEL a br l ou le fil d amen e est cass Remplacez la DEL L appa...

Page 22: ...llez toujours la lentille du d tecteur avant de l ins rer V rifier la qualit de l eau voir les param tres la page 2 ROUGE ALLUM E ALLUM E Le d tecteur UV n a pas d tect une intensit UV suffisante pour...

Page 23: ...V UNIT CB 2440A 2 CARTE DE CIRCUIT FOR 230V UNIT RN 001 CROU DE RETENUE CP 1240 COUVERCLE DE LA CARTE DE CIRCUIT CS 001 Q CORDON D ALIMENTATION 120V CS EU Q CORDON D ALIMENTATION EUROP EN 230V DP750 B...

Page 24: ...SSANCE DE LA LAMPE 39 W 39 W 78 W 78 W 156 W PRESSION MAXIMUM D OP RATION 8 62 bar 12 lb po2 8 62 bar 125 psi 8 62 bar 125 psi 8 62 bar 125 psi 8 62 bar 125 psi TEMP RATURE AMBIANTE 2 40 C 36 104 F 2...

Reviews: