background image

2

I

NSTALLING

Y

OUR

D

ISINFECTION

S

YSTEM

:

•  The complete water system, including any pressure or hot water tanks, must be sterilized before start up by flushing

with chlorine (household bleach) to destroy any residual contamination.

•  The disinfection system should be connected to a ground fault interrupter.
•  The disinfection system is intended for indoor use only, do not install disinfection system where it may be exposed to 

the weather.

•  Install the disinfection system on cold water line only.
•  If treating the entire house, install the disinfection system before any branch lines. Ideally, your disinfection system

should be the last treatment your water receives prior to use.

•  A 5 micron sediment filter must precede the disinfection system.

1.

Remove the disinfection system from the shipping carton.  For shipping purposes, the UV lamp is packed in a 

separate tube.  Set the lamp aside for use later.  The disinfection system should be mounted in the horizontal 
position, with the inlet/outlet ports facing up.  If the system must be installed in the vertical position, make sure 
the inlet port is the one at the bottom of the system.  Mount the unit in a clear space with at least 36” (91.5 cm) 
of space at the lamp end to facilitate lamp and or quartz sleeve removal.  Fasten the disinfection system to a 
suitable mounting platform with reinforcements.

2.

It is recommended to install a suitable flow restrictor in order that the flow rate not exceed the manufacturers 

recommended flow rating.  The use of a by-pass with shut-off valves is recommended for emergency use of 
untreated water when your disinfection system is being serviced.  Apply two turns of Teflon tape around the port 
threads to ensure a tight joint before connecting unions.

Note: 

When the UV unit has been by-passed for service, the complete water system must be sterilized once 

again with chlorine to destroy any contamination that may have passed during by-pass.  

DO NOT SOLDER CONNECTIONS WHILE ATTACHED TO THE DISINFECTION SYSTEM AS THIS COULD DAMAGE THE 
O-RING SEALS.

3.

When all plumbing connections are made, 

slowly 

turn on the water supply and check for leaks.  The most likely 

cause for leaks is from the o-ring seal.  In case of a leak, shut water off, drain cell, remove the retainer nut, wipe 
the o-ring and threads clean and re-install.

4.

Once it is determined that there are no leaks, 

very carefully

slide the UV lamp into the UV chamber making sure 

the lamp pins are accessible for connection with the lamp connector cable.  

Attach the lamp connector to the UV 

lamp, as outlined in “UV Lamp Replacement” on page 3

.  Plug the disinfection system into the ground fault 

interrupter, and check to see if the UV lamp is illuminated.  

NEVER LOOK DIRECTLY AT THE BURNING UV 

LAMP

. Allow the water to run for a few minutes to clear any air or dust that may be in the cell.

Note:

When there is no flow, the water in the cell will become warm, as the UV disinfection system lamp is always

on.  To remedy this, run a cold water tap anywhere in the house for a minute to flush out the warm water.

Note

:

As the system requires time to reach its full operating capacity, please allow the disinfection system to operate

3 - 5 minutes prior to using the water from the unit. In addition, to clear any air or debris from the system, open
the faucet and allow water to run through the disinfection system for 2 - 3 minutes.

W

ATER

C

HEMISTRY

:

Water quality is extremely important for the optimum performance of your UV system. The following levels are 
recommended for installation:

•  Iron: < 0.3 ppm (0.3 mg/L)
•  Hardness*: < 7 gpg (120 mg/L)
•  Turbidity: < 1 NTU
•  Manganese: < 0.05 ppm (0.05 mg/L)
•  Tannins: < 0.1 ppm (0.1 mg/L)
•  UV Transmittance: > 75% (call factory for 

recommendations on applications where UVT < 75%)

*  Where total hardness is less than 7 gpg, the UV unit should operate efficiently provided the quartz sleeve is 

cleaned periodically.  If total hardness is over 7 gpg, the water should be softened.

If your water chemistry contains levels in excess of those mentioned above, proper pre-treatment is recommended to 
correct these water problems prior to the installation of your UV disinfection system. These water quality parameters can
be tested by your local dealer, or by most private analytical laboratories.  Proper pre-treatment is essential for the UV 
disinfection system to operate as intended.

Summary of Contents for Sterilight S12Q

Page 1: ...er s Manual P N 520022 October 2004 425 Clair Road West P O Box 1719 Guelph ON N1H 7X4 Canada t 519 763 1032 f 519 763 5069 t f 1 800 265 7246 e water r can com i www r can com S12Q S12Q GOLD S24Q S24...

Page 2: ...Chemistry Page 2 Installing Your Disinfection System Page 2 Operating Maintenance Instructions Page 3 4 Warning Systems Page 4 5 Warranty Page 5 Troubleshooting Page 6 8 Parts Page 9 Specifications P...

Page 3: ...temperatures below freezing Do not store this disinfection system where it will be exposed to the weather Do not store this disinfection system where it will be exposed to temperatures below freezing...

Page 4: ...nnections are made slowly turn on the water supply and check for leaks The most likely cause for leaks is from the o ring seal In case of a leak shut water off drain cell remove the retainer nut wipe...

Page 5: ...The connector is keyed and will only allow correct installation in one position Ensure the connector is fully seated onto the UV lamp 3 Once the lamp is fully seated on the connector slide the connect...

Page 6: ...tection by constantly sensing the UV INTENSITY at the inside surface of the cell The system features a single LED indicator light which will show three distinct colours GREEN YELLOW and RED When the U...

Page 7: ...cable for remote monitoring of the audible and visual signals provided by the UV monitoring mechanism THIS ADVANCED WARNING SYSTEM HAS BEEN INSTALLED TO PROVIDE YOU WITH THE OPTIMUM PRECAUTIONS TO EN...

Page 8: ...the disinfection system it is imperative that the effluent water stream be shocked with chlorine after the water leaves the disinfection system the disinfection system must have a bacteria free distr...

Page 9: ...ALARM UV LAMP ON ON OFF ON Correct operating conditions unit is functioning properly OFF OFF OFF OFF The unit is not plugged into the electrical outlet Plug unit into receptacle and ensure proper powe...

Page 10: ...acturer replacement Always Wet Sensor Lens prior to inserting sensor check water quality see page 2 for water parameters RED ON ON UV Sensor has not detected enough UV Intensity to adequately protect...

Page 11: ...IRCUIT BOARD for 115V unit CB 2440A 2 CIRCUIT BOARD for 230V unit RN 001 ALUMINUM RETAINING NUT CP 1240 CIRCUIT BOARD COVER CS 001 Q CORD SET 115V CS EU Q EUROPEAN SCHUKO CORD SET 230V DP750 RETAINING...

Page 12: ...ER CONSUMPTION 42 W 42 W 95 W 95 W 190 W TOTAL LAMP WATTS 39 W 39 W 78 W 78 W 156 W MAXIMUM OPERATING PRESSURE 8 62 bar 125 psi 8 62 bar 125 psi 8 62 bar 125 psi 8 62 bar 125 psi 8 62 bar 125 psi AMBI...

Page 13: ...N 520022 octobre 2004 425 chemin Clair ouest C P 1719 Guelph ON N1H 7X4 Canada t l 519 763 1032 s f 1 800 265 7246 t l c 519 763 5069 courriel water r can com site Internet www r can com EPA 57987 CN...

Page 14: ...miques de l eau Page 2 L installation de votre syst me de d sinfection Page 2 Directives d utilisation et d entretien Page 3 4 Syst mes d advertissement Page 4 5 Garantie Page 5 Diagnostic Page 6 8 Co...

Page 15: ...toujours l alimentation d eau d un syst me de d sinfection et sa prise lectrique avant de commencer son nettoyage ou son entretien Ne tirez jamais sur le cordon pour le d brancher de la prise murale...

Page 16: ...ntenue dans le compartiment se r chauffe s il n y a pas d coulement Pour rem dier cette situation laisser couler pendant une minute un robinet d eau froide de la maison Vous vacuerez ainsi l eau chaud...

Page 17: ...est bien cal sur la lampe UV 3 D s que la lampe est bien fix e au connecteur glissez le sur l crou de retenue en aluminium Assurez vous que la bague m tallique de retenue du connecteur n emp che pas c...

Page 18: ...OUR VOUS PROCURER UNE PROTECTION OPTIMALE CONTRE LA CONTAMINATION MICROBIOLOGIQUE DE VOTRE EAU NE N GLIGEZ PAS LES AVERTISSEMENTS LUMINEUX LA MEILLEURE FA ON DE V RIFIER LE BON FONCTIONNEMENT DE VOTRE...

Page 19: ...otre d taillant Cette vanne sol no de qui est normalement ferm fonctionne en parall le avec le syst me de contr le UV pour arr ter l coulement de l eau si le capteur UV d tecte qu elle n est pas trait...

Page 20: ...d utilisation de cet appareil Contamination apr s le syst me de d sinfection Il est imp ratif que l eau effluente re oive un traitement de choc au chlore apr s que l eau quitte le syst me de d sinfec...

Page 21: ...M E TEINTE ALLUM E Conditions de fonctionnement correctes l appareil fonctionne correctement TEINTE TEINTE TEINTE TEINTE L indicateur est DEL a br l ou le fil d amen e est cass Remplacez la DEL L appa...

Page 22: ...llez toujours la lentille du d tecteur avant de l ins rer V rifier la qualit de l eau voir les param tres la page 2 ROUGE ALLUM E ALLUM E Le d tecteur UV n a pas d tect une intensit UV suffisante pour...

Page 23: ...V UNIT CB 2440A 2 CARTE DE CIRCUIT FOR 230V UNIT RN 001 CROU DE RETENUE CP 1240 COUVERCLE DE LA CARTE DE CIRCUIT CS 001 Q CORDON D ALIMENTATION 120V CS EU Q CORDON D ALIMENTATION EUROP EN 230V DP750 B...

Page 24: ...SSANCE DE LA LAMPE 39 W 39 W 78 W 78 W 156 W PRESSION MAXIMUM D OP RATION 8 62 bar 12 lb po2 8 62 bar 125 psi 8 62 bar 125 psi 8 62 bar 125 psi 8 62 bar 125 psi TEMP RATURE AMBIANTE 2 40 C 36 104 F 2...