FAN WILL NOT START

1.

   Check that the electricity has been 

turned on at the circuit breaker which had 
probably been turned off during 
installation.

2. 

  Turn off the electricity.  Check all 

connections in the wiring of the fan at the 
wall and make sure it follows the wiring 
instructions outlined in this manual.

NOISE

Note:

 Always allow a day or two "run-in" 

time for any new fan at medium or high 
speed.  When attempting to diagnose 
noise, listen carefully from several sides 
to try and isolate the location of the noise 
(fan base, blade, fan cage, motor, etc.)

1.  

Check to see that all screws are tight in 

the fan cage connection to the motor face 
plate.

2. 

  Turn off the power.  Loosen the fan 

base and check that the wiring and/or wire 
nut connectors are not resting against the 
fan base, possibly vibrating while the fan 
is on.

3.

   Use of a standard light rheostat or an 

unapproved fan wall control to control the 
fan speed will always cause an annoying 
"hum".  Many fan motors do not work 
quietly with solid state variable speed 
controls.

7. TROUBLESHOOTING

REPLACEMENT PARTS AVAILABLE

A full range of genuine replacement 
spare parts are available at reasonable 
cost directly form Quorum 
International.  Please call us at (817) 
626-5483.  Monday through Friday 
from 8:00 A.M. to 5:00 P.M. CST.

Summary of Contents for The Veranda

Page 1: ...read and save these instructions These instructions are to be used in the installation of the following QUORUM INTERNATIONAL fans The Veranda P O Box 961008 Fort Worth TX 76161 817 626 5483 FAX 817 626 5540 IO220 01 14 2014 Quorum International All Rights Reserved ...

Page 2: ...estions regarding the warranty or the procedures for obtaining service please call us at 817 626 5483 Monday thru Friday 8 00 a m 5 00 p m CST technical skill competence or experience of the user 8 Light bulbs glass or acrylic components or accessories 9 Minor occurrences of wobble are accepted as normal and should not necessarily be considered a defect WHO MAY ENFORCE WARRANTY This warranty may b...

Page 3: ... the National Electrical Code If you are unfamiliar with electric wiring please use a qualified and licensed electrician 4 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 5 Before applying power visually re inspect the installation Make sure that all guards and protective devices are securely in place and all visible screws and bolts are tig...

Page 4: ...l junction box or make sure the existing box is secured directly to the building structure Use appropriate fasteners and building materials CAUTION TO REDUCE THE RISK OF PERSONAL INJURY INSTALL THE PRIMARY MOUNTING MEANS AND USE ONLY THE HARDWARE PROVIDED WITH THE FAN 3 MOUNTING OPTIONS WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK FIRE OR PERSONAL INJURY MOUNT THE FAN ONLY TO AN OUTLET MARKED ACCE...

Page 5: ...he wall mounting plate ensure the two hanging bars sliding into the notch of hook completely Figure 5 NOTE Make sure the two wire connectors are revealed through the wireway passage after hanging the fan motor assembly onto the wall mounting plate 7 Make the connection for the two wire connectors and then tuck the wires inside the fan base Figure 5 8 Re install the fan base screws that removed pre...

Page 6: ...unit Remove the existing wall plate and switch from the wall junction box Connect blue wire labeled FOR OSCILLATION from wall control to blue or red wire from wall junction box Connect black wire labeled TO MOTOR L from wall control to black wire from wall junction box Connect the black white wire labeled AC IN L from the wall control to the black wire from A C supply source If your wall junction ...

Page 7: ...hould see a significant reduction in your cooling costs by regular use of your fan 2 A clicking or a rattling noise is a sure indication of loosening screws Since screws will invariably work loose over time at least once a year tighten all the screws for this fan 3 Clean you fan periodically using only a cloth dampened with a mild detergent solution for all hardware never use solvents The finish p...

Page 8: ... cage motor etc 1 Check to see that all screws are tight in the fan cage connection to the motor face plate 2 Turn off the power Loosen the fan base and check that the wiring and or wire nut connectors are not resting against the fan base possibly vibrating while the fan is on 3 Use of a standard light rheostat or an unapproved fan wall control to control the fan speed will always cause an annoyin...

Reviews: