5. ELECTRICAL CONNECTIONS

Use 

ONLY

 wall controls approved by 

Quorum. Use of unapproved wall 
controls will cause unacceptable 
humming noise, and avoids the fan 
warranty.

NOTE:

 The wire connection for this fan 

requires that a three-conductor cable 
with ground wire be run between ceiling 
and wall junction box, or the oscillating 
feature will not work.

Hook up in "series only" do 

not

 connect 

the hot and neutral wires of electric 
circuit to the wall control - damage to 
the wall control and possible fire could 
occur. 

REMEMBER 

-Turn off the power!

Use the wire nuts supplied with your fan 
when making connections. Secure the 
connectors with electrical tape and make 
sure there are no loose connections or wire 
strands.

Connect the wiring from the wall switch 
receptacle to the wall control unit.

●  Remove the existing wall plate and 
switch from the wall junction box.

●  Connect blue wire (labeled “FOR 
OSCILLATION) from wall control to blue 
or red wire from wall junction box,

●  Connect black wire (labeled “TO 
MOTOR L) from wall control to black 
wire from wall junction box. 

●  Connect the black/white wire (labeled 
“AC IN L”) from the wall control to the 
black wire from A/C supply source.

●  If your wall junction box has a ground 
wire (green or bare copper), connect the 
wall control’s yellow/green ground wire to 
it; otherwise connect the wall control’s 
yellow/green ground wire directly to one 
of the screws from the wall junction box.

●  Carefully tuck the connected wires 
inside the junction box. Secure the wall 
control with the two screws provided. 
Attach the face plate over the wall control 
with the two screws provided.

Fig. 7

Fan base

Wall junction 

box

Wall junction 

box

Wall

BLUE

WH

WH

BLK

BLK

BLK

BLK

BLK

BLK

YELLOW/GREEN

BLK/WH

BLUE or RED

BLUE

House 

supply 

wire

Wall control

BLUE or RED

Summary of Contents for The Veranda

Page 1: ...read and save these instructions These instructions are to be used in the installation of the following QUORUM INTERNATIONAL fans The Veranda P O Box 961008 Fort Worth TX 76161 817 626 5483 FAX 817 626 5540 IO220 01 14 2014 Quorum International All Rights Reserved ...

Page 2: ...estions regarding the warranty or the procedures for obtaining service please call us at 817 626 5483 Monday thru Friday 8 00 a m 5 00 p m CST technical skill competence or experience of the user 8 Light bulbs glass or acrylic components or accessories 9 Minor occurrences of wobble are accepted as normal and should not necessarily be considered a defect WHO MAY ENFORCE WARRANTY This warranty may b...

Page 3: ... the National Electrical Code If you are unfamiliar with electric wiring please use a qualified and licensed electrician 4 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 5 Before applying power visually re inspect the installation Make sure that all guards and protective devices are securely in place and all visible screws and bolts are tig...

Page 4: ...l junction box or make sure the existing box is secured directly to the building structure Use appropriate fasteners and building materials CAUTION TO REDUCE THE RISK OF PERSONAL INJURY INSTALL THE PRIMARY MOUNTING MEANS AND USE ONLY THE HARDWARE PROVIDED WITH THE FAN 3 MOUNTING OPTIONS WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK FIRE OR PERSONAL INJURY MOUNT THE FAN ONLY TO AN OUTLET MARKED ACCE...

Page 5: ...he wall mounting plate ensure the two hanging bars sliding into the notch of hook completely Figure 5 NOTE Make sure the two wire connectors are revealed through the wireway passage after hanging the fan motor assembly onto the wall mounting plate 7 Make the connection for the two wire connectors and then tuck the wires inside the fan base Figure 5 8 Re install the fan base screws that removed pre...

Page 6: ...unit Remove the existing wall plate and switch from the wall junction box Connect blue wire labeled FOR OSCILLATION from wall control to blue or red wire from wall junction box Connect black wire labeled TO MOTOR L from wall control to black wire from wall junction box Connect the black white wire labeled AC IN L from the wall control to the black wire from A C supply source If your wall junction ...

Page 7: ...hould see a significant reduction in your cooling costs by regular use of your fan 2 A clicking or a rattling noise is a sure indication of loosening screws Since screws will invariably work loose over time at least once a year tighten all the screws for this fan 3 Clean you fan periodically using only a cloth dampened with a mild detergent solution for all hardware never use solvents The finish p...

Page 8: ... cage motor etc 1 Check to see that all screws are tight in the fan cage connection to the motor face plate 2 Turn off the power Loosen the fan base and check that the wiring and or wire nut connectors are not resting against the fan base possibly vibrating while the fan is on 3 Use of a standard light rheostat or an unapproved fan wall control to control the fan speed will always cause an annoyin...

Reviews: