![Quonset Microwave QM1003-0.5-18-2 User Manual Download Page 45](http://html1.mh-extra.com/html/quonset-microwave/qm1003-0-5-18-2/qm1003-0-5-18-2_user-manual_3770233045.webp)
QM1003-0.5-18-2 Dual Channel RF Downconverter
User Manual
2.3 FREQuency:MODE <numeric value>
This command allows the user to set the converter mode of the QM1003-0.5-18-2 for both channels. The
mode setting controls the converter bypass, the input amp, and the output amp. The range of acceptable
mode values is 0-4 and are described as follows:
Table 4.6:
Converter Operation Modes
Converter Mode
Converter Status
Input Amplifier
Input Amplifier
0
Bypassed
Off
Off
1
Enabled
Off
Off
2
Enabled
Off
On
3
Enabled
On
Off
4
Enabled
On
On
Syntax
:
FREQ
:
MODE
Space
Numeric Value
?
Example
:FREQ:MODE 1
This command sets the converter mode of the QM1003-0.5-18-2
to 1, which enables the converter, and disables both the input and
output amplifiers
.
Default Condition
On power up, or when a
*RST
command is issued, the QM1003-0.5-18-2 returns to the boot state’s
setting. The Dual Channel RF Downconverter default setting is 1.
Query
:FREQ:MODE?
This query returns the converter mode of the QM1003-0.5-18-2.
Error Message
If the parameter is not in the recognized format, error
-102, "Syntax error"
occurs.
If the parameter is not between 0 and 4, error
-222, "Data out of range"
occurs.
Quonset Microwave
Revision 1.0.0
34
Summary of Contents for QM1003-0.5-18-2
Page 7: ...QM1003 0 5 18 2 Dual Channel RF Downconverter User Manual Quonset Microwave Revision 1 0 0 vi...
Page 38: ...QM1003 0 5 18 2 Dual Channel RF Downconverter User Manual Quonset Microwave Revision 1 0 0 27...
Page 100: ...Quonset Microwave www quonsetmicrowave com 1003 005 21 1003 005 21 Revision 1 0 0 March 2023...