Release: 06 / 2019 

 
 
 

2 levels 

 
The module support has 2 levels: 
 
- the SMD level, for a focus of 100% (optimum sharpness), the 
support is provided on the two angle strips with a clearance height of 
about 50 mm. 
 
- the THT level, with a reduced focus at the bottom PCB level of th
assembly (unsuitable for SMD component testing) is the support on 
the lower lugs of the side stops and the magnetic
level is intended for assemblies with high THT components with a 
clearance height of 60 mm. 
 
Applies to all LC20, LCM20, -/UV, and LCM25 models
 
 

Maintenance work 

 
To maintain the QuinsBox, you only need to periodically clean the 
white initialization plate, depending on dust deposition
experience, once a year), with a dry dust rag
streaks on the surface! To do this, remove the drawer from the box 
and slowly squeeze the scan carriage with your hand to the left so 
that you can comfortably reach the initialization plate by hand and 
remove the dust with the rag. 
(It also makes sense to free the drawer of lost parts, simply remove, 
turn, and shake it out) 
 
 
The white balance is firmware controlled, is fully automatic before each scan and can never be changed! This 
ensures that a color change of the image recordings, despite possibly weaker lighting is not possible. An 
additional calibration does not take plac
of order (red LED). In this case, it is only possible to continue working after replacing the lighting unit.
 
Applies to all models! 

 
Quins System LCM20 / LCM20UV

 
 

Connections 

 
All LCM models have only a power and network connection and a WLAN 
antenna. 
 

Fuse 

There is a fuse slot between the power connector and the central power 
switch: 
- 1,6 A, 250 V, T 
 

Rollers with brakes 

To make sure the device does not roll away,
please always use the brakes on the front wheels
 
 

Control elements 

(see page 8) 
 
 
 

 

page   - 10 -

 

or a focus of 100% (optimum sharpness), the 

support is provided on the two angle strips with a clearance height of 

with a reduced focus at the bottom PCB level of the 

assembly (unsuitable for SMD component testing) is the support on 
the lower lugs of the side stops and the magnetic-foot stopper. This 
level is intended for assemblies with high THT components with a 

/UV, and LCM25 models. 

To maintain the QuinsBox, you only need to periodically clean the 

, depending on dust deposition, (According to 

with a dry dust rag. Do not create any 

To do this, remove the drawer from the box 

and slowly squeeze the scan carriage with your hand to the left so 
that you can comfortably reach the initialization plate by hand and 

free the drawer of lost parts, simply remove, 

The white balance is firmware controlled, is fully automatic before each scan and can never be changed! This 
ensures that a color change of the image recordings, despite possibly weaker lighting is not possible. An 
additional calibration does not take place. Too low illumination causes an initialization error and the box goes out 
of order (red LED). In this case, it is only possible to continue working after replacing the lighting unit.

Quins System LCM20 / LCM20UV 

All LCM models have only a power and network connection and a WLAN 

the power connector and the central power 

To make sure the device does not roll away, 
please always use the brakes on the front wheels. 

 

The white balance is firmware controlled, is fully automatic before each scan and can never be changed! This 
ensures that a color change of the image recordings, despite possibly weaker lighting is not possible. An 

e. Too low illumination causes an initialization error and the box goes out 

of order (red LED). In this case, it is only possible to continue working after replacing the lighting unit. 

Summary of Contents for LC20

Page 1: ...Manual Release 06 2019 Quins LC20 Quins LC20 UV Quins LC25 Quins LCM20 Quins LCM20 UV Quins LCM25 Quins Hardware www quins de ...

Page 2: ...ress Central page 2 Address Central Service Owner Klaus Kornhaas Wohnpark 1 95189 Brunnenthal Germany Phone 49 0 9281 67212 Fax 49 0 9281 62635 Email support quins de URL www quins de FTP downloads at ftp Quins Support de ...

Page 3: ...20 UV Transport safety Drawer Inserting assemblies for testing 2 levels Maintenance work Quins System LCM20 LCM20UV Connections Fuse Rollers with brakes Control elements Quins computer QuinsBox LC25 Quins System LCM25 Connections Control elements Transport safety Drawer Maintenance work Decleration of Conformity Technical data of the Quins hardware page 3 justment Quins System LCM25 Technical data...

Page 4: ...ation For the use of the Quins hardware always the respective driver program must be installed The correct Twain drivers are included in the corresponding EPSON Scan programs With this program the Quins hardware can be operated without Quins programs as a normal scanner Verwenden Sie das entsprechende Epson Scan Programm für die jeweilige Quins Hardware EPSON GT 15000 LC20 31317eu exe EPSON GT 150...

Page 5: ...ate manipulation on the computer automatically leads to the blocking of the software and repaired for a fee Also the uninstallation and reinstallation does not change anything You should therefore activate the software in good time before the end of the test phase QuinsLicense lic for your computer receive the license file by sending us your order and the key file created with our software You mus...

Page 6: ...uins de Please send technical update information to _____________________________________________________________ _____________________________________________________________ _________ ___________________________________________________ Mr Mrs ____________________________________________________ _____________________________________________________________ Mr Mrs _________________________________...

Page 7: ...side of your Quins box Please note if you reinstall the Quins software or if you connect another Quins box to the system computer these entries page 7 Scanner Settings In the Reference Scan window you must set the data of the QuinsBox once Scan Systems Settings Adjustment In the top line the correct Quins Box type Scan System must be selected so that the scan program accesses the The Map settings ...

Page 8: ...different light type This will be activated at the next scan start Transport safety Attention to transport the QuinsBox you should sna so that the scan carriage does not mov can be broken off When shipping the box the transport lock Applies to all LC models page 8 QuinsBox LC20 LC20UV Unlock the transport lock and plug the power cord into port slot black socket When connecting to a 3 0 slot blue s...

Page 9: ...ed Make sure that the assembly is not moved when moving the drawer in The magnetic foot stopper is normally required for the free the assembly Applies to all LC20 LCM20 UV and LCM25 models page 9 Behind the drawer is located on each side of a stop bracket with magnet which hold the drawer when inserted in the end position The drawer must always be up to the stop it means until the magnets hold the...

Page 10: ...always use the brakes on the front wheels Control elements see page 8 page 10 or a focus of 100 optimum sharpness the support is provided on the two angle strips with a clearance height of with a reduced focus at the bottom PCB level of the assembly unsuitable for SMD component testing is the support on the lower lugs of the side stops and the magnetic foot stopper This level is intended for assem...

Page 11: ...ardware Accessories Maintenance work see page 10 page 11 computer delivery date the Quins calculator is always a current model of an external supplier since 2007 DELL Please observe the operating instructions of the respective manufacturer This applies analogously to the monitor keyboard and mouse that are included in the system Also the conditions of the currently installed Windows operating syst...

Page 12: ... Image capture unit Quins LCM20 LCM25 LCM20 UV Inspection software Quins easy of the company Quins owner Klaus Kornhaas Wohnpark 1 D 95189 Brunnenthal requirements of the Council Directives on the approximation of the laws of the Member machines 98 37 EEC Electromagnetic Compatibility Directive 89 336 EEC and concerning electrical resources 73 23 EEC each on the last version prior agreement Part o...

Page 13: ...32 x 310 mm 3 8 ms line colour 1 3 ms line black white 490 x 390 mm space in the drawer 600 x 390 mm space in the drawer SMD level 50 mm 65 mm distance down THT level 60 mm 55 mm distance down 10 mm double row LED illumination with 308 LED s respectively 308 additional UV LED s 1 600 candela at 50 mm distance USB 2 0 80 W during scanning PC in optimized equipment 3 5 GHz 8 GB RAM 500 GB SSD 24 Tou...

Page 14: ...lease 06 2019 Tel 49 0 92 81 6 43 45 Fax 49 0 92 81 6 26 35 page 14 Klaus Kornhaas Wohnpark 1 D 95189 Brunnenthal Germany Tel 49 0 92 81 6 43 45 Fax 49 0 92 81 6 26 35 Mail info quins de URL www quins de ...

Reviews: