QHPR Installation & Operating Instructions
Removing Condensate
A separator with an automatic drain valve
is supplied with each dryer. The user must
install a separate discharge line at the drain
connection to discharge condensate to
an environmentally approved condensate
collection/disposal system. Securely anchor
drain line to prevent whipping.
If clogging of the automatic drain is a
problem, install a particulate filter before
the dryer to keep solid particles from
entering the dryer. Contact your local
distributor for the appropriate particulate
filter.
Electrical Connections
The dryer is designed to operate on the
voltage, phase and frequency listed on the
serial number tag. Reference the tag prior
to making an electrical connection. Dryers
are supplied with a cord and plug. Install in
receptacle of proper voltage.
CaUtion!
Operation of dryers with improper line
voltage constitutes misuse and could
affect the dryer warranty.
Instrumentation
ON/OFF Switch
QHPR dryers are equipped with an ON/
OFF switch on the front panel. A light
signals when the dryer is on.
Condensate Drain Valve
A float operated drain housed in a
metal bowl will automatically drain the
condensate on all QHPR model dryers.