OWNER'S MANUAL 

WARRANTY  •  OPERATING INSTRUCTIONS  •  SAFETY  

MAINTENANCE  •  SPECIFICATIONS  •  PARTS LIST 

 

 

 

 

 

 

 

 

 

 

 

 

 

DRIZAIR 120 REFRIGERANT 

DEHUMIDIFIER 

This manual has important safety warnings and operating information.  

Please read before using the dehumidifier and save for future reference.

 

PURCHASE DATE:

 ________________________________ 

  SERIAL NO.: 

 ______________________________________   

DEALER: 

 ____________________________________________________________________________________________________ 

 

 

DRI-EAZ PRODUCTS, INC. • 1320 Josh Wilson Road, Burlington WA 98233 • (360) 757-7776

 

Summary of Contents for DRIZAIR 120

Page 1: ...nings and operating information Please read before using the dehumidifier and save for future reference PURCHASE DATE ________________________________ SERIAL NO ______________________________________ DEALER ____________________________________________________________________________________________________ DRI EAZ PRODUCTS INC 1320 Josh Wilson Road Burlington WA 98233 360 757 7776 ...

Page 2: ...shock or fire in the event of an electrical hazard Danger Removal or alteration of the grounding plug or use of an adapter that defeats the dehumidifier s electrical grounding can create risk of serious personal injury or fire in the event of damage to or malfunction of this product Do not use the dehumidifier if you cannot connect it to a receptacle that accepts a three pronged plug If you are un...

Page 3: ...eriod of two 2 years from date of purchase During the first 90 days Dri Eaz will cover all material labor and shipping costs to and from the service center After the 90 days the customer is responsible for shipping costs to the Service Center After one 1 year the customer is responsible for labor costs and shipping costs to and from the service center Compressor and Coils Warranty Dri Eaz will rep...

Page 4: ...from one location to another The sturdy handle and wheels allow the unit to be rolled rather than lifted or carried This reduces the possibility of damage to the unit or of injury to the operator OPERATING CONDITIONS The DrizAir 120 industrial grade dehumidifier is designed to operate in cooler conditions than most home owner units It will operate at temperatures down to 33 F and up to 100 F 0 38 ...

Page 5: ...e of the building in a reasonable time the relative hu midity of the air should be about 40 Rh at 70 F 21 C In most cases the air has to be dried artificially to reduce it to 40 Rh It is important that when the hu midity is greater than 40 outside all doors and win dows are kept closed Defrosting When the DrizAir 120 is operating at a room tem perature of 68 F 20 C or higher water will normal ly e...

Page 6: ...rating If there is any doubt about voltage then it should be tested at the unit on compressor start up If there is a dip of more than 10 from the no minal supply rating then action should be taken to im prove the supply Under no circumstances should the unit be left operating As the length of cable increases the voltage available at the unit decreases The follow ing table provides a guide to maxim...

Page 7: ... with a vacuum cleaner and brush attachment Danger Do not under any circumstances remove the round grounding plug from the cord To do so will increase the risk of personal injury shock or fire Electrical Wiring Cord Inspect the power cord periodically to ensure insu lation is in good condition Remove the dehumidifier cover and control panel plate and ensure that all wires are secured away from the...

Page 8: ...do not need to be removed 5 Remove the used tubing in a U shaped pattern clockwise starting from the top left side Discon nect the tube from the hose fittings 6 Clean the roller race removing any articles that could damage tubing Check the rollers for loose ness or binding The rollers must fit snugly on the shaft and spin freely See the Troubleshooting sec tion for guidelines if a problem exists 7...

Page 9: ...ting 6670 BTU Power Required 80 F 60 Rh 6 amps Peristaltic Pump Only 0 35 amps Lighted Splash Guard Power Switch On Off Operating Range Fahrenheit 33 100 F Operating Range Celsius 0 38 C Water Removal at 80 F 60 Rh 64 pints Water Removal at 90 F 90 Rh 120 pints Specifications are subject to change without notice Some values are approximate ...

Page 10: ...ompressor AST 4 Replace or repair compressor 5 Defective relay AST 5 Use Volt amp meter to check relay Fan blade not turning 1 Obstructed or bent fan blade 2 Loose fan blade nut 3 Loose or broken wire 4 Burned out fan motor AST FS AST AST 1 Remove obstruction or replace fan blade 2 Tighten fan blade nut 3 Replace broken wire 4 Replace fan motor Dehumidifier operating but room not dry 1 Not enough ...

Page 11: ...ure 3 Increase airflow or clean out coils Water overflowing the tray while using gravity drain hose 1 Unit not in level position 2 Gravity drain hose kinked FS FS 1 Make sure dehumidifier is level 2 Straighten hose and remove kinks Pump not functioning properly 1 Cracked or distorted pump body 2 Excessive shaft side play 3 Worn rollers 4 Frozen rollers AST AST AST AST 1 Replace pump 2 Replace pump...