background image

QHPR Installation & Operating Instructions

Safety Precautions

Pressurized Devices

This equipment is a pressure containing 

device.

• Do not exceed maximum operating 

pressure as shown on equipment serial 

number tag.

• Make sure equipment is depressurized 

before working on or disassembling it 

for service.

Electrical

This equipment requires electricity to 

operate.

• Install equipment in compliance with all 

applicable electrical codes.

• Standard equipment is supplied with 

electrical enclosures not intended for 

installation in hazardous environments.

• Disconnect power supply to equipment 

when performing any electrical service 

work.

Breathing Air

• Air treated by this equipment may not 

be suitable for breathing without further 

purification.

Refer to applicable standards and 

specifications for the requirements for 

breathing quality air.

Receiving, Unpacking and Moving

Receiving

This shipment has been thoroughly 

checked, packed and inspected before 

leaving our plant.  It was received in 

good condition by the carrier and was so 

acknowledged.
Check for visible loss or damage.  If 

this shipment shows evidence of loss or 

damage at time of delivery to you, insist 

that a notation of this loss or damage 

be made on the delivery receipt by the 

carrier’s agent.

Unpacking

Check for Concealed Loss or Damage.  

When a shipment has been delivered to 

you in apparent good order, but concealed 

damage is found upon unpacking, notify 

the carrier immediately and insist on his 

agent inspecting the shipment.  Concealed 

damage claims are not our responsibility as 

our terms are F.O.B. point of shipment.

Moving

In moving or transporting dryer, do not tip 

dryer onto its side.

Storage

IMPORTANT:    Do  not  store  dryer  in 

temperatures above 130°F (54.4°C).

 

Quincy Compressor-QHPR Series Dryers

Summary of Contents for QHPR Series

Page 1: ...uction Manual This manual contains important safety information and should be made available to all personnel who operate and or maintain this product Carefully read this manual before attempting to o...

Page 2: ......

Page 3: ...Precautions 2 Receiving Unpacking and Moving 2 Installation 3 Instrumentation 4 Start up Operation 5 Shutdown 5 Maintenance 6 Returns to Manufacturer 7 Field Service Guide 7 Troubleshooting 8 Technica...

Page 4: ......

Page 5: ...urer must first be authorized by the manufacturer Unauthorized service voids the warranty and any resulting charge or subsequent claim will not be paid Products repaired or replaced under warranty sha...

Page 6: ...ons for the requirements for breathing quality air Receiving Unpacking and Moving Receiving This shipment has been thoroughly checked packed and inspected before leaving our plant It was received in g...

Page 7: ...evel Anchor bolts are not required System Arrangement Liquid water in the inlet air will adversely affect the performance of the dryer Install the dryer downstream of an aftercooler or separator so th...

Page 8: ...for the appropriate particulate filter Electrical Connections The dryer is designed to operate on the voltage phase and frequency listed on the serial number tag Reference the tag prior to making an e...

Page 9: ...ation or call your local distributor b Confirm that condensate is discharging from the drain This can only be done when there is air flow through the dryer Reference Serial Number Tag for appropriate...

Page 10: ...enser coils Remove accumulated dust and dirt with a soft brush or with air from an OSHA approved compressed air nozzle that limits the discharge pressure to 30 psig General For continued good performa...

Page 11: ...e water downstream of the dryer and excessive pressure drop Most causes can be identified and remedied by following this guide Closed refrigeration systems are potentially dangerous Work on the refrig...

Page 12: ...ambient temperature Improper adjustment of Expansion Valve Remedy Replace float mechanism Check aftercooler discharge temperature and reduce to dryer design condition 122 F max Consult local distribut...

Page 13: ...ssible causes Dryer undersized may cause water downstream of dryer Blocked separator Dryer freezing up Remedy Check airflow and dryer capacity Reduce airflow or resize and replace dryer Dismantle clea...

Page 14: ...t Typeb R 134A R 134A MINIMUM MAXIMUM OPERATING CONDITIONS Min Max Inlet Air Pressure compressed air at inlet to dryer 30 250 psig 30 250 psig Min Max Inlet Air Temperature compressed air at inlet to...

Page 15: ...TER S M COMP 1PH C OVERLOAD PROTECTOR Air Refrigerant Flow Schematic HEAT EXCHANGER REHEATER AUX CONDENSER AIR OUTLET SEPARATOR EVAPORATOR CHILLER DRAIN OUTLET AIR INLET LIQUID RECEIVER FILTER DRYER R...

Page 16: ...seller freight prepaid for inspection Seller warrants repaired or replaced parts of its own manufacture against defects in materials and workmanship under normal use and service for ninety 90 days or...

Page 17: ...nd storage charges may be applied at the discretion of Seller Accounts past due shall bare interest at the highest rate lawful to contract for but if there is no limit set by law such interest shall b...

Page 18: ...___________________________ __________________________________________________________________________ __________________________________________________________________________ ______________________...

Page 19: ......

Page 20: ...2009 Quincy Compressor All Rights Reserved Litho in U S A Dryer Department 724 746 1100 SPXDocument 5003991 E mail info quincycompressor com Website quincycompressor com...

Reviews: