Unit
Type
R410a
Total amount (approx.)
- QED 650
lb
4.41
- QED 650
kg
2
- QED 850
lb
6.17
- QED 850
kg
2.8
- QED 1050
lb
7.5
- QED 1050
kg
3.4
QED 650
Performance data
Unit
At ambient
temperature of:
°F
100
77
86
95
104
115
At ambient
temperature of:
°C
38
25
30
35
40
45
Volume flow at dryer
inlet under nominal
conditions
cfm
657
657
657
657
657
657
Volume flow at dryer
inlet under nominal
conditions
l/s
310
310
310
310
310
310
Pressure dew-point
˚F
39
36
37
43
55
66
Pressure dew-point
˚C
4
2
3
6
13
19
Total power
consumption
hp
6.2
4.8
5.5
6.3
7.1
7.6
Total power
consumption
kW
4.6
3.6
4.1
4.7
5.3
5.7
Power consumption,
cooling fan
hp
0.9
0.9
0.9
0.9
0.9
0.9
Power consumption,
cooling fan
kW
0.7
0.7
0.7
0.7
0.7
0.7
Cooling air flow
(approx.)
cfm
3600
3600
3600
3600
3600
3600
Cooling air flow
(approx.)
l/s
1700
1700
1700
1700
1700
1700
Heat dissipated by
cooling air flow
(approx.)
Btu/hr
37500
34100
40900
47800
51200
64800
Heat dissipated by
cooling air flow
(approx.)
kW
11
10
12
14
15
19
Instruction book
2920 1818 00
93
Summary of Contents for QED 650
Page 5: ...9 Pressure equipment directives 96 Instruction book 4 2920 1818 00...
Page 12: ...General view of QED 850 Instruction book 2920 1818 00 11...
Page 14: ...Position of components Inside view of QED 650 Instruction book 2920 1818 00 13...
Page 15: ...Inside view of QED 850 Instruction book 14 2920 1818 00...
Page 26: ...Electrical diagram QED 650 Instruction book 2920 1818 00 25...
Page 27: ...Electrical diagram QED 850 and QED 1050 Instruction book 26 2920 1818 00...
Page 78: ...Dimension drawing of QED 850 Instruction book 2920 1818 00 77...
Page 98: ......
Page 99: ...Cod 2920 1818 00 Edition 09 2012 quincycompressor com info quincycompressor com 217 222 7700...