General description
2.1
Introduction
Description
The air dryers remove moisture from compressed air by cooling the air to near freezing point. This causes
water to condense. The condensate is automatically drained. The air is warmed up before leaving the dryer
(approx. 5 ˚C (9 ˚F) below the incoming air temperature).
The
Air Logic Controller
(1) keeps the pressure dew-point stable at no load by opening or closing the
solenoid
valve of the hot-gas by-pass.
The condenser has a cooling fan controlled by a pressure sensor.
General view
General view of QED 650
Instruction book
10
2920 1818 00