Unit
60 Hz
Maximum ambient air temperature
°C
50
Maximum ambient air temperature
°F
122
Minimum compressed air inlet temperature
°C
1
Minimum compressed air inlet temperature
°F
34
Maximum compressed air inlet temperature
°C
60
Maximum compressed air inlet temperature
°F
140
8.3
Air dryer data
All data specified below apply under reference conditions, see section
Specific data
Air dryer type
Units
QED-250
QED-300
QED-350
Volume flow at dryer inlet
60 Hz
l/s
120
150
185
Volume flow at dryer inlet
60 Hz
cfm
254
318
392
Pressure drop over dryer without filters,
approx.
60 Hz
bar
0.11
0.14
0.22
Pressure drop over dryer without filters,
approx.
60 Hz
psi
1.60
2.03
3.19
Total power consumption, including cooling fan 60 Hz
kW
1.5
1.5
2.3
Total power consumption, including cooling fan 60 Hz
hp
2.28
3.22
3.08
Refrigerant type
R410a
R410a
R410a
Refrigerant charge (approx.)
kg
0.86
0.86
0.92
Refrigerant charge (approx.)
lb
1.90
1.90
2.03
Dryer mass (approx.)
kg
170
170
185
Dryer mass (approx.)
lb
375
375
408
Air dryer type
Units
QED-450
QED-500
QED-600
Volume flow at dryer inlet
60 Hz
l/s
220
245
285
Volume flow at dryer inlet
60 Hz
cfm
466
519
604
Pressure drop over dryer without filters,
approx.
60 Hz
bar
0.12
0.18
0.22
Pressure drop over dryer without filters,
approx.
60 Hz
psi
1.74
2.61
3.19
Total power consumption, including cooling fan 60 Hz
kW
2.5
2.9
3.1
Total power consumption, including cooling fan 60 Hz
hp
3.49
3.89
4.16
Refrigerant type
R410a
R410a
R410a
Refrigerant charge (approx.)
kg
1.55
1.20
1.28
Refrigerant charge (approx.)
lb
3.42
2.65
2.82
Instruction book