Never exceed the designed pressure for the system or overload the
motor beyond its Maximum Amp Draw.
* Full Load Amps x Service Factor = Maximum Amp Draw
Never assume a compressor is safe to work on just because it is not
operating. It may be in the automatic stand-by mode and may
restart any time. Follow all safety precautions outlined in SEC-
TION 5,
Stopping For Maintenance.
Torquing Cylinder to Head Capscrews
Torque cylinder to head capscrews to specifications listed in the parts book
corresponding to the Record of Change for your compressor. Then, run the
compressor for at least 1 hour. Shut the unit off and follow precautions outlined
in
SECTION 5,
Stopping for Maintenance.
Retorque the head capscrews to
same specifications after the unit has cooled.
WARNING !
WARNING !
* Full load amps (FLA) & Service Factor can usually be found on the motor nameplate.
†
Reference torque spec. note in parts book corresponding to Record of Change for your compressor.