Industrial / Air Master Series
Quincy Compressor
50161-105, March 2008
22
3501 Wismann Lane, Quincy Ill. - 62305-3116
Do not open a manual tank drain valve on any air tank containing
more than 30 PSIG of air pressure!
Never attempt to relieve an air tank by removing a pipe plug or any
other system component!
Manually Draining An Air Tank:
Step 1)
Disconnect & lockout the compressor from the
power source (electric models) or disconnect the spark
plug wire from the spark plug (gas engine models).
Step 2)
Tanks subjected to freezing temperatures may
contain ice. Store the compressor in a heated area
before attempting to drain moisture from the tanks.
Reduce the air pressure in the tank to 30 PSIG by
pulling the pressure relief valve ring (refer to
Fig. 3-10,
Checking Pressure Relief Valves & Relieving
System Pressure
).
Step 3)
Open the drain valve and allow the moisture
and air mixture to drain from the tank.
Step 4)
Once the moisture has been completely drained,
close the drain valve.
Pix 1160
Fig. 3-10 Checking Pressure Relief Valves
& Relieving System Pressure
WARNING !
WARNING !