background image

1-888-QUIETCOOL 

2

CONTENTS

1. SYSTEM OVERVIEW  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.1   Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2   Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3   System Venting Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

2. INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

2.1   Installing AFG Model Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.2   Installing AFG Vent Covers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3. WIRING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3.1   Thermostat Wiring - AFG PRO-2.0   . . . . . . . . . . . . . . . . . . . . . . . 6
3.2   Remote Thermostat Wiring - AFG PRO-2.0   . . . . . . . . . . . . . . . . 7

4. SYSTEM OPERATING INSTRUCTIONS   . . . . . . . . . . . . . . . . . . . . . . . . 9

4.1   Setting the Thermostat  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.2   How to Use Attic Fans  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

QC MANUFACTURING, INC.

26040 YNEZ ROAD

TEMECULA, CA 92591

PHONE

 1-888-QUIETCOOL

WEBSITE

 WWW.QUIETCOOLSYSTEMS.COM

WARNINGS 

CAUTION: 

This unit has an unguarded impeller. Do not use in locations readily 

accessible to people or animals.

CAUTION: 

Do not operate any fan with a damaged cord or plug. Discard fan 

or return to an authorized service facility for examination and/or repair.

CAUTION:

 Do not run cord under carpeting. Do not cover cord with throw 

rugs, runners, or similar coverings. Do not route cord under furniture or 

appliances. Arrange cord away from traffic area and where it will not be 

tripped over.

CAUTION:

 Automatically started device. To reduce the risk of injury, 

disconnect from power supply before servicing. Do not use fan with any solid 

state speed control device. For residential use only.

!

!

!!

!!

!!

Summary of Contents for AFG PRO-2.0

Page 1: ...DO NOT THROW AWAY SERIAL NUMBER FOR FAN IS LOCATED ON THE BACK COVER OF THE OWNER S GUIDE LEAVE WITH HOMEOWNER OWNER S GUIDE PRO ATTIC GABLE FAN AFG PRO 2 0...

Page 2: ...STEMS COM WARNINGS CAUTION This unit has an unguarded impeller Do not use in locations readily accessible to people or animals CAUTION Do not operate any fan with a damaged cord or plug Discard fan or...

Page 3: ...standard thermostat this attic fan will transform your attic into a cool oasis QuietCool Attic Fans work almost everywhere anytime During the summer an attic can be 40 50 degrees hotter than the outsi...

Page 4: ...or effectively as it could with 1 750 attic venting But don t worry the system will still operate if there is not enough venting Insufficient venting is a very simple problem to fix Roofing contractor...

Page 5: ...Mount The AFG can be mounted on a wide louver but additional mounting steps must be taken in order for the fan to work properly As shown in Figure 2 1B two additional boards must be fastened to the bo...

Page 6: ...ced electrician NOTE Your fan came with the Adjustable Thermostat pre wired on High Speed to a power cord for testing purposes before installation If you would like to hard wire the fan or it is requi...

Page 7: ...d screw Specialty Series Fan Power Source 14 2 Wire 14 2 Wire 60 Thermostat FAN ON TEMPERATURE 90 120 ADJUSTABLE TEMPERATURE THERMOSTAT CAUTION Automatically started device to reduce the risk of injur...

Page 8: ...2 wire Romex 8 Tie the two remaining black wires together Then tie the remaining copper wires together Ground the fan to the junction box using the green ground screw Specialty Series Fan Junction Box...

Page 9: ...rature is at or above the set temperature To change the setting of the thermostat simply take a screwdriver and twist the dial The thermostat also includes a Fire Fuse that will turn off the attic fan...

Page 10: ...armer months of the year With an attic fan running during the summer we have seen attic temperature maintain as low as a 5 F difference between the outside temperature and the attic temperature WINTER...

Page 11: ...from the operation of our equipment or any malfunction thereof 2 Cost of service calls to diagnose the cause of problems or the labor charge to un install any components 3 Product failure or damage d...

Page 12: ...FAN SERIAL NUMBER INFORMATION RETAIN FOR YOUR RECORDS SERIAL NUMBER IS REQUIRED FOR WARRANTY PURPOSES 1 888 QUIETCOOL WWW QUIETCOOLSYSTEMS COM Rev 4 16 20...

Reviews: