4

Return Inlet  

     Flow Outlet

Installation 

1.  Hang the boiler up in a vertical position on 

fixing screws with the inlet and outlet pipes 

to  the  bottom,  maintaining  clearances  from 

the walls and the ceiling. 

2.  Connect  the  boiler  to  the  central  heating 

system equipped with a cut-off valves. 

3.  Fill the central heating system with a treated 

water that substantially extends the life of the 

heating elements.

4.  Vent the central heating system.

5.  Connect a boiler to the electrical system.

6.  Fix the room thermostat, in accordance with 

manual instruction. 

7.  Connect the room thermostat (by using two 

wires 2 x 0,35 mm

2

) to the terminal of control 

panel (RP entry).

8.  Once you have finished the above procedures, 

you can start the boiler. See the „Start-up” section.

            While applying thermostat make sure there is no voltage on its entry!

Do not connect any voltage into RP, NA, WZ entries! This can result in perma-

nent controller damage.

!

N

L

1

2

N

L

1

Connection to the three-phase electrical system.

 

PNL  -  points of neutral and protective conductor 

connection

 

PF  -  points of phase conductors connection

 

[1]  -  temperature limiter

Connection to the single phase electrical system  

(for boilers of 4kW,6kW and 8kW)

 

PNL  -  connection points of neutral, protective and 

phase conductors

 

[1]  -  temperature limiter

 

[2]  -  additional  conductors  (for  single  phase 

system only)

Important: 4, 6 and 8kW boilers are factory preset to work as single phase boilers. 

If you intend to connect the boiler to a three-phase system, take off the [2] wire set.

Summary of Contents for EKCO.L2

Page 1: ...ELECTRIC CENTRAL HEATING FLOW BOILER QuickTec GmbH Bardelebenweg 25 14089 Berlin Germany Tel 49 0 30 577 01 88 40 Fax 49 0 30 577 01 88 49 E Mail mail quick tec com quick tec com...

Page 2: ...for recycling Appropriate utilisation of used product prevents potential negative environmental influences that may occur as a result of inappropriate handling of waste In order to get more detailed...

Page 3: ...l is equipped with a differential pressure relief valve bypass It allows the system to keep minimal flow of heating medium through the boiler and reduce noises in installation during the thermostatic...

Page 4: ...entry 8 Once you have finished the above procedures you can start the boiler See the Start up section While applying thermostat make sure there is no voltage on its entry Do not connect any voltage i...

Page 5: ...xtra expansion vessel should be installed on it Temperature of heating medium feed and return Capacity of central heating system Pressure in central heating system C l bar 85 70 58 1 5 70 55 79 55 45...

Page 6: ...not run close to mains cables they must not go around other electric wires Important To activate the sensor and DHW cylinder heating please follow the in structions in section ADVANCED SETTINGS Set up...

Page 7: ...try so that when a master appliance gets on the contact will be opened the boiler switched off When the NA contact gets opened heating will get off and the pump stopped The EKCO LN2 and EKCO L2 model...

Page 8: ...n the table below set the appropri ate mode according to the following instructions press button for longer than 2 seconds but less than 10 seconds LED s will start to flash the pump then switches to...

Page 9: ...external external thermostat the close open contact is connected to Tzas entry If the DHW cylinder mode is inactive this parameter is unavailable installation pressure sensor active 1 or inactive 0 i...

Page 10: ...nt Do not cut power supply off between heating season When the control panel is switched to Stand by mode the control panel is off the F icons flickers only In this mode the boiler is off but the pump...

Page 11: ...ing system is off When and icons are on it shows that the boiler is in C H DHW mode When you switch to this mode the control panel is in the main view display an icons show current working mode The di...

Page 12: ...r is on inlet temp D and K indicators are on outlet temp D and L indicators are on medium flow rate through the boiler B indicator is on pressure in the system A indicator is on power with which the b...

Page 13: ...CO L2 boiler heats the DHW icon is on all models temp in CH system is lower than required but the required room temperature has been reached RP entry is open or room thermostat is blocked EKCO LN2 EKC...

Page 14: ...act an authorised service or the seller G indicator is off in winter mode a failure of installation that con nect a room thermostat contact an authorised service or the seller a failure of electronic...

Page 15: ...0 27 0 17 0 15 0 27 Rated power kW 12 15 18 21 24 Rated voltage 400V 3N Rated current A 3x17 3 3x21 7 3x26 0 3x30 3 3x34 6 Fuse rated current A 20 25 32 40 Min connecting wires section mm2 5 x 2 5 5...

Page 16: ...QuickTec GmbH Bardelebenweg 25 14089 Berlin Germany Tel 49 0 30 577 01 88 40 Fax 49 0 30 577 01 88 49 E Mail mail quick tec com quick tec com...

Reviews: