3

GB-031AB/f.

Safety instructions

1.  Read and strictly follow the installation and operating instructions to ensure a 

long life and reliable boiler operation. 

2.  An efficient electrical installation which has been completed in accordance with 

the binding norms of electric installation.

3.  A wet central heating system equipped with appropriate expansion vessel made 

according to binding norms of hydraulic installation.

4.  A wet central heating system must be flushed before boiler installation.

5.  Do not install any barrier fittings (e.g. valves) on the outlet of the safety valve.

6.  Boiler must be installed on an even wall surface. 

7.  Boiler must not be installed in a humid place or in a place exposed to the danger 

of explosion.

8.  Boiler installation and all electrical and hydraulic work must be performed by a 

qualified professional installer.

9.  All installation work must be performed when the power and water supply is 

turned off.

10.  EKCO.LN2 and EKCO.LN2...p model is equipped with a differential pressure 

relief valve (bypass). It allows the system to keep minimal flow of heating medium 

through the boiler and reduce noises in installation during the thermostatic valves 

closing.

11.  Electric installation should be equipped with residual current protective devices 

and other solutions which will ensure disconnecting the heater from the source 

of power (intervals between all their poles should not be less than 3 mm).

12.  Boiler is pre-set by the manufacturer to work with the central heating system. 

Change the factory settings („Extended Menu”) to boiler work with DHW Cylinder.

13.  Do not drain the water from central heating system after the heating season.

14.  Leave the controller in stand-by mode and do not cut off power supply between 

the heating seasons.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities or lack of experience and knowledge, unless they have been given supervision or 

instruction concerning use of the appliance by a person responsible for their safety. 

Children should be supervised to ensure that they do not play with the appliance.

Summary of Contents for EKCO.L2

Page 1: ...ELECTRIC CENTRAL HEATING FLOW BOILER QuickTec GmbH Bardelebenweg 25 14089 Berlin Germany Tel 49 0 30 577 01 88 40 Fax 49 0 30 577 01 88 49 E Mail mail quick tec com quick tec com...

Page 2: ...for recycling Appropriate utilisation of used product prevents potential negative environmental influences that may occur as a result of inappropriate handling of waste In order to get more detailed...

Page 3: ...l is equipped with a differential pressure relief valve bypass It allows the system to keep minimal flow of heating medium through the boiler and reduce noises in installation during the thermostatic...

Page 4: ...entry 8 Once you have finished the above procedures you can start the boiler See the Start up section While applying thermostat make sure there is no voltage on its entry Do not connect any voltage i...

Page 5: ...xtra expansion vessel should be installed on it Temperature of heating medium feed and return Capacity of central heating system Pressure in central heating system C l bar 85 70 58 1 5 70 55 79 55 45...

Page 6: ...not run close to mains cables they must not go around other electric wires Important To activate the sensor and DHW cylinder heating please follow the in structions in section ADVANCED SETTINGS Set up...

Page 7: ...try so that when a master appliance gets on the contact will be opened the boiler switched off When the NA contact gets opened heating will get off and the pump stopped The EKCO LN2 and EKCO L2 model...

Page 8: ...n the table below set the appropri ate mode according to the following instructions press button for longer than 2 seconds but less than 10 seconds LED s will start to flash the pump then switches to...

Page 9: ...external external thermostat the close open contact is connected to Tzas entry If the DHW cylinder mode is inactive this parameter is unavailable installation pressure sensor active 1 or inactive 0 i...

Page 10: ...nt Do not cut power supply off between heating season When the control panel is switched to Stand by mode the control panel is off the F icons flickers only In this mode the boiler is off but the pump...

Page 11: ...ing system is off When and icons are on it shows that the boiler is in C H DHW mode When you switch to this mode the control panel is in the main view display an icons show current working mode The di...

Page 12: ...r is on inlet temp D and K indicators are on outlet temp D and L indicators are on medium flow rate through the boiler B indicator is on pressure in the system A indicator is on power with which the b...

Page 13: ...CO L2 boiler heats the DHW icon is on all models temp in CH system is lower than required but the required room temperature has been reached RP entry is open or room thermostat is blocked EKCO LN2 EKC...

Page 14: ...act an authorised service or the seller G indicator is off in winter mode a failure of installation that con nect a room thermostat contact an authorised service or the seller a failure of electronic...

Page 15: ...0 27 0 17 0 15 0 27 Rated power kW 12 15 18 21 24 Rated voltage 400V 3N Rated current A 3x17 3 3x21 7 3x26 0 3x30 3 3x34 6 Fuse rated current A 20 25 32 40 Min connecting wires section mm2 5 x 2 5 5...

Page 16: ...QuickTec GmbH Bardelebenweg 25 14089 Berlin Germany Tel 49 0 30 577 01 88 40 Fax 49 0 30 577 01 88 49 E Mail mail quick tec com quick tec com...

Reviews: