background image

10

Control panel

 

A -  pressure [bar] 

 

B -  flow [l/min] 

 

C -  power [kW] 

 

D -  temperature [0

°

C] 

 

E -  digital display 

 

F -  indicator of medium temperature setting 

(for DHW cylinder) 

 

G -  indicator of room thermostat and heating 

activity (for central heating) 

 

H -  indicator of pump and flow activity 

 

I,J -  inactive indicators 

 

K -  inlet temp. indicator 

 

L -  outlet temp. indicator 

 

M -  indicator of boiler activity (for central 

heating) 

 

N -  indicator  of  boiler  activity  (for  DHW 

cylinder) 

 

O -  control buttons

The control panel consists of two working areas: the signalling area (elements: A-N) 

and control area (O). The user can select the following working modes: 

stand-by, winter (CH heating or CH + DHW heating), summer (DHW heating) for 

EKCO.LN2 and EKCO.L2,

stand-by, winter (CH heating) for EKCO.LN2...p and EKCO.L2...p.

To switch between working modes press 

.

Stand-by mode 

To set the stand-by mode press 

. and hold for 3 seconds. Important: Do not cut 

power supply off between heating season. When the control panel is switched to 

„Stand-by” mode the control panel is off (the F icons flickers only). In this mode the 

boiler is off but the pump is activated every day for 15 minutes (what protects the 

boiler and the whole central heating installation from being blocked and silted up). 

The pump will run every day at the same time, it will be the time of the day when you 

switch it to the „Stand-by” mode e.g., if you set the pump on a „Stand-by” mode at 6 

p.m. the timer will activate the pump everyday for 15 minutes starting at around 6 p.m. 

To check out the installation pressure press 

 or 

 To set the winter mode press 

, (when you set from „Stand-by” to „Winter mode”). 

type of flow sensor – (1) HC DN 15 sensor, (2) KOSPEL sensor,

work-time counter of boiler (read-only time). Counter display shows figures (with-

out leading zeros) starting from the most important with 1/2 second intervals, the 

display will turn off (for 2 seconds) when the least important figure is shown, 

Press and hold the 

 button to exit and save the settings.

Summary of Contents for EKCO.L2

Page 1: ...ELECTRIC CENTRAL HEATING FLOW BOILER QuickTec GmbH Bardelebenweg 25 14089 Berlin Germany Tel 49 0 30 577 01 88 40 Fax 49 0 30 577 01 88 49 E Mail mail quick tec com quick tec com...

Page 2: ...for recycling Appropriate utilisation of used product prevents potential negative environmental influences that may occur as a result of inappropriate handling of waste In order to get more detailed...

Page 3: ...l is equipped with a differential pressure relief valve bypass It allows the system to keep minimal flow of heating medium through the boiler and reduce noises in installation during the thermostatic...

Page 4: ...entry 8 Once you have finished the above procedures you can start the boiler See the Start up section While applying thermostat make sure there is no voltage on its entry Do not connect any voltage i...

Page 5: ...xtra expansion vessel should be installed on it Temperature of heating medium feed and return Capacity of central heating system Pressure in central heating system C l bar 85 70 58 1 5 70 55 79 55 45...

Page 6: ...not run close to mains cables they must not go around other electric wires Important To activate the sensor and DHW cylinder heating please follow the in structions in section ADVANCED SETTINGS Set up...

Page 7: ...try so that when a master appliance gets on the contact will be opened the boiler switched off When the NA contact gets opened heating will get off and the pump stopped The EKCO LN2 and EKCO L2 model...

Page 8: ...n the table below set the appropri ate mode according to the following instructions press button for longer than 2 seconds but less than 10 seconds LED s will start to flash the pump then switches to...

Page 9: ...external external thermostat the close open contact is connected to Tzas entry If the DHW cylinder mode is inactive this parameter is unavailable installation pressure sensor active 1 or inactive 0 i...

Page 10: ...nt Do not cut power supply off between heating season When the control panel is switched to Stand by mode the control panel is off the F icons flickers only In this mode the boiler is off but the pump...

Page 11: ...ing system is off When and icons are on it shows that the boiler is in C H DHW mode When you switch to this mode the control panel is in the main view display an icons show current working mode The di...

Page 12: ...r is on inlet temp D and K indicators are on outlet temp D and L indicators are on medium flow rate through the boiler B indicator is on pressure in the system A indicator is on power with which the b...

Page 13: ...CO L2 boiler heats the DHW icon is on all models temp in CH system is lower than required but the required room temperature has been reached RP entry is open or room thermostat is blocked EKCO LN2 EKC...

Page 14: ...act an authorised service or the seller G indicator is off in winter mode a failure of installation that con nect a room thermostat contact an authorised service or the seller a failure of electronic...

Page 15: ...0 27 0 17 0 15 0 27 Rated power kW 12 15 18 21 24 Rated voltage 400V 3N Rated current A 3x17 3 3x21 7 3x26 0 3x30 3 3x34 6 Fuse rated current A 20 25 32 40 Min connecting wires section mm2 5 x 2 5 5...

Page 16: ...QuickTec GmbH Bardelebenweg 25 14089 Berlin Germany Tel 49 0 30 577 01 88 40 Fax 49 0 30 577 01 88 49 E Mail mail quick tec com quick tec com...

Reviews: