13
EN
DIMMER RGBW - REV003A
QUICK SPA
ON
on
off
Use good-quality, twisted, shielded cables suitable for serial communication. Make
the connections following the information above.
TERMINATE THE LINE ON THE LAST MODULE OF THE NETWORK BY
TURNING THE Tline DIP SWITCH “ON”.
Serial communication cables
SELECTIONS
The operating mode can be selected by DIP switch:
1 2 3 4 5 6
ON
1 2
3
4
5
6
7 8 9
0
1 2
3
4
5
6
7 8 9
0
ON
SELECT
ADDRESS
TLine
6-position DIP switches for setting operating mode
SELECT
Dip 1-3 = not enabled (reserved for other functions)
Dip 4 = Local/Remote mode
Off = locale / On = local and remote
Dip 5 = not enabled (reserved for other functions)
Dip 6 = type of light: white light/RGBW
Off = white / On = RGBW
ADDRESS
Rotary switches for setting device address (max. 99 modules)
TLine
DIP switch for connecting the load on the communication line in remote mode (last module)
SIGNALS
DIAGNOSTICS
LED INPUTS
STATUS
n° 4+2
On
Enabled
Off
Not enabled
LED OUTPUTS
STATUS
n° 4
On o Off
Output
Flashing
Output protected against overcurrents and short circuits
STATUS LED
POWER IN - F1 e F2
n° 2
On
Power supply connected
Off
No power supply or blown fuse
STATUS LED
CPU activity (ready)
n° 1
Flashing
CPU active and power supply connected
Off
No power supply or CPU blocked
On
CPU blocked
OPERATION / SIGNALS
SIGNALS