![background image](http://html1.mh-extra.com/html/quick/hdim300/hdim300_manual-of-use-and-maintenance_3637147006.webp)
6
QUICK SPA
CHARACTERISTICS / INSTALLATION
EN
DIMMER HDIM300 - REV001A
READ CAREFULLY BEFORE CONNECTING THE DIMMER
Dimmer HDIM300 is a device specially designed to vary the light intensity produced by incandescent lamps. Any other use is incorrect. Quick
S.p.A. cannot be prosecuted for any damage due to an incorrect installation or an incorrect connection or an incorrect use of the device. The
correct installation, connection and use is described in the present paper.
WARNING
• DO NOT over load HDIM300. The load factor cannot be higher than the maximum described in the Label Data below.
• Connect the polarities as described in the Connection Diagrams below.
• DO NOT INSTALL HDIM300 in proximity of DC fluorescent lamps.
• Push Buttons must be connected by double-wire cables.
• Use separate cables to supply HDIM300 and the lamps connected to it.
• HDIM300 must be installed in proper ventilated places and kept out from heat and humidity.
Quick S.p.A. will not be responsible in case of wrong connection and misuse of this device.
READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THE DIMMER.
IN CASE OF DOUBT, CONTACT YOUR DEALER OR QUICK
®
CUSTOMER SERVICE.
THE PACKAGE CONTAINS:
HDIM300 - conditions of warranty - the manual of installation and use.
F
MASTER UNIT CONNECTION
REMOTE UNIT CONNECTION
10 - 11
Positive power supply (+Vin)
10 - 11
Positive power supply (+Vin)
12 - 13
Negative power supply (- Vin)
12 - 13
Negative power supply (- Vin)
16 - 17
Connection to Remote Unit
16 - 17
Connection to Remote Unit
1 - 2
Positive lamps (+Vout
pulse)
1 - 2
Positivs lamps (+Vout
pulse)
3 - 4
Negativs lamps (-Vout
pulse)
3 - 4
Negativs lamps (-Vout
pulse)
7 - 9
Push buttons
7 - 9
Connection to Master Unit
15
Power-on light
15
Power-on light
INSTALLATION AND CONNECTION DIAGRAM
Installation
Bar DIN EN50.022 : Make sure the device is firmly fixed and locked to avoid side slipping.
Connecting terminals
Good to ensure a resistant hold even for wires with no clamped ends.
Protection
Internal 15A Fuse, against short circuits of the load.
Control type
HDIM300 MASTER: Push-Button.
Unlimited number
HDIM300 SLAVE: signal from
HDIM300 MASTER
NOTES
Follow the polarity and the Connection Diagram below. Connect to Direct Current (DC).
Use cables of appropriate section.
Always provide an appropriate protection to the dimmer source.
Before installing HDIM300 verify that your batteries are powerful enough to supply Energy to your max load.
CARATTERISTICHE
Soft Start
HDIM300 activates a soft start dimming function to make bulbs long lasting.
Dimming Voltage Range
On model HDIM300-15/100 minimum luminosity is set to starting from 15%
in order not to leave the dimmer under voltage when light is off.
On model HDIM300-0/100 minimum luminosity is set to starting from 0%.
Input voltage
10 ÷ 30 Vdc
Full load absorption
11,25 A
Max load
HDIM300 MASTER: 150W @ 12V / 300W @ 24V
HDIM300 SLAVE: 150W @ 12V / 300W @ 24V
Absorption in Stand-by
20mA
Operating temperature
from +5°C to +50°C
Storage temperature
from -40°C to + 70°C
Case material
IP 20
Dimensions
52 x 88 x 58 mm ( 2
3
/
64
x 3
29
/
64
x 2
49
/
64
)
Certifications
CE marking according to CEI EN 60945
Summary of Contents for HDIM300