Plug In Dimmer

ZLINK PD-100 is a Z-Wave Plus® cer�fied device with S2 security and SmartStart 

features. You can now add this device securely and with ease using QR code on the 

product with compa�ble gateways suppor�ng S2 and Smart Start. PD-100 is a 

member of the Z-Wave family and communicates with other Z-Wave cer�fied 

devices in a control network. PD-100 can be used to turn any plug in lamps On, Off, 

or control dimming of any lamps with dimmable light bulbs. Each Z-Wave device also 

serves as a node to repeat the signal in the network, thus, extending the overall 

Z-Wave mesh wireless network range. Different types and brands of Z-Wave devices 

can be associated with the PD-100 in your system and they will work together to 

op�mize and expand the coverage of your Z-Wave network. For more informa�on on 

this and other quality ZLINK Products please visit www.ZLINKProducts.com. 

Works with any AC operated lamps with incandescent and dimmable 

florescent (CFL) or LED light bulbs

ON/OFF status and loca�on LED indicator

Remotely or manually turns ON or OFF, or DIM lights

Does not block the second AC outlet

Z-Wave 500 Series module inside

Internal rese�able fuse to protect from surge current

Works with any cer�fied gateway suppor�ng Z-Wave

Z-Wave 500 Series module inside

Please find the QR code label with DSK on the bo�om of the device.

This product speaks 

with other Z-Wave 

cer�fied devices

INTRODUCTION

FEATURES

The connected ligh�ng devices can be controlled manually with a push bu�on 

OR Wirelessly with a remotely

Manual Reset

A Z-Wave cer�fied controller is capable of se�ng up ZLINK products in your 

desired network. Once the device is added, you may assign it to a Group.  

Furthermore, it can be set in Associa�on with another Z-Wave device to 

perform a specific triggered func�on such as turning lights on when mo�on 

is detected. Please refer to the instruc�ons manual of your controller for 

details and procedures on how these se�ngs can be done. 

BASIC OPERATION

Step 3

 Add (Include) the module into your network by a Z-Wave cer�fied controller. 

Please refer to your gateway’s or the controller’s instruc�ons manual for details.

Plug the 2-pin AC power plugs of ligh�ng 

device to the receptacle of PD-100.

Step 1

! WARNING !

RISK OF FIRE, ELECTRICAL SHOCK & BURNS

DO NOT USE WITH MEDICAL AND LIFE SUPPORT INSTRUMENT 

No user serviceable parts are in this module

To reduce the risk of electric shock, this product has a grounding type plug that has a 

third (grounding) pin. This plug will only fit into a grounding type power outlet. If the 

plug does not fit into the outlet, contact a qualified electrician to install the proper 

outlet. Do not change the plug in any way

CAUTION: To Reduce the Risk of Overhea�ng And Possible Damage To Other 

Equipment, Do Not Install To Control A Motor-Operated Appliance, 

A Non-Dimmable Fluorescent Ligh�ng Fixture, Or A Transformer-Supplied Appliance

The ligh�ng devices connected to this Z-Wave module must not exceed 2.5A, 300W 

incandescent, 65W dimmable CFL/LED.

SETUP

Step 2

Insert the module's 3-pin plug into an AC 

outlet in the same room as your gateway. 

In normal opera�ng mode, the LED on the 

front panel will be lit.

Normally, the sequence is as follows: 

1. Place your network controller into inclusion mode by following the controller 

manufacturer's instruc�ons.

2. When the controller is ready, single click the bu�on on the front of PD-100.  

The controller should indicate that the new device was added successfully

3. Once PD-100 has been successfully added to your home network, you can 

move it to the preferred loca�on in the home.
If the controller shows it failed, repeat the procedure.

If Inclusion s�ll fails a�er the 2nd a�empt, you need to first reset the PD-100 

before repea�ng the above step. The manual reset method is as follows:

3. Plug the PD-100 back into the AC outlet with the bu�on pressed

A�er 3 seconds, release the bu�on. If you see the bu�on blink, that means that 

PD-100 has been reset successfully and you may retry Step 3 above to add the 

module into your network. Otherwise, please repeat the manual reset procedure.   
Note: If the PD-100 was previously Added (Included) in your network, rese�ng it 

locally does not mean it has been removed from your network. If you wish to 

remove PD-100 from your network you will need to Delete (Exclude) the module 

from the network by your controller.
Use the manual reset procedure only in the event that the network primary 

controller is lost or otherwise inoperable. 

About the push bu�on:

There is a single bu�on on PD-100 for manual opera�on that: 

This push bu�on is also backlit with an LED indicator that will be On when the 

connected appliance is Off, and vice versa. The module may be easily spo�ed 

even in a dark environment. 

Manually turns the connected ligh�ng ON/OFF by pressing the bu�on. It 

func�ons as a toggle switch; if the light is ON, pressing the bu�on turns 

the light OFF and vice a versa.

Adjust the brightness level of the connected ligh�ng by pressing and 

holding the bu�on. Release the bu�on when the desired level is reached. 

It func�ons as a toggle switch as well. The ligh�ng keeps dimming un�l the 

minimum level is reached or the bu�on is released. When you press the 

bu�on again and hold, the brightness of the light will keep increasing un�l 

the maximum level is reached or when the bu�on is released.

Adds(Includes) or Deletes(Excludes) your PD-100 to/from your Z-Wave 

network. Please refer to the instruc�ons manual of your gateway or 

remote controller for detail procedures on how these ac�ons can be done.

In the event of a power failure, the ZLINK device will return to the last dimming 

level a�er the power is restored.

www.ZLINKProducts.com

Connecting Things That Matter

www.ZLINKProducts.com

PD-100 User Guide


Press here

A)

B)

C)

2. Press and hold the bu�on on the PD-100.

1. Unplug PD-100 from the AC outlet and 

also unplug the power plug of the 

appliance from PD-100 (if plugged in).