background image

 

 
 

DMX-LED-Dimmer XS3 

 
 
 
 
 
 

User Manual 

 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 

 

 

 

Summary of Contents for 90- 3373

Page 1: ...DMX LED Dimmer XS3 User Manual ...

Page 2: ...ring and or if the board has been improperly soldered all warranty claims will be voided and no repair will be carried out Content Description 3 Data Sheet 4 Content 4 Connection 5 Cable Length 6 DMX Addressing 7 Color Sequence 7 LED Display 7 Operation Modes 8 Personality 1 3Ch Dimmer 8 Personality 2 3Ch Dimmer Master 8 Personality 3 3Ch Dimmer Master Strobe 8 DMX FAIL Action 9 RDM 10 Create Use ...

Page 3: ... to 100 For voltages from 12V up to 24V The DMX LED Dimmer XS3 runs with a power supply from 12V up to 24V DMX FAIL Function An adjustable DMX FAIL Function offers the option to get in case of lost DMX signal the current state HOLD or assuming a preset value DMX Master dimmer Optionally another DMX channel can be activated as master dimmer all outputs RDM support The DMX LED Dimmer XS3 allows conf...

Page 4: ... channels depend on Personality DMX FAIL Hold 0 100 StandAlone Output 3 PWM Signals with 8 Bit resolution Common power supply Output Current max 2A per output max 6A in sum for all outputs Output Power 3x 24W 12V 3x 48W 24V PWM Frequency 244 Hz StandAlone Function User defined light program Dimension 12mm x 40mm Content 1x DMX LED Dimmer XS3 1x Quick guide german and english ...

Page 5: ...DMX LED Dimmer XS3 5 Connection V OUT1 OUT2 OUT3 12V R G B 12V GND DMX DMX DMX IN DMX OUT DMX LED Dimmer XS3 ...

Page 6: ...n voltage in LED installation the cable cross section is to choose as large as possible to keep the voltage drop as low as possible on the cable The wire cross section should be all the larger as the distance increases and the load increases The following cable lengths should not be exceeded From power supply to DMX LED Dimmer XS3 10m ...

Page 7: ... can be configured to correspond with the used LED stripe The colour sequence is to set via the RDM Parameter COLOR_SEQUENCE LED Display The integrated blue LED is a single color multi functional display During the DMX operation the LED lights up nonstop In this case the device is working Also the LED signalled the error status In this case the LED lights up in short pitches and then and then turn...

Page 8: ... Personality 1 3Ch Dimmer Personality 2 3Ch Dimmer Master Personality 3 3Ch Dimmer Master Strobe Personality 1 3Ch Dimmer RED GREEN BLUE Personality 2 3Ch Dimmer Master MASTER RED GREEN BLUE Personality 3 3Ch Dimmer Master Strobe STROBE MASTER RED GREEN BLUE Start address Start address Start address ...

Page 9: ...D outputs on the last value to use a predefined DMX value or to execute a user defined program The DMX Fail action is to set via the RDM Parameter DMX_FAIL_MODE After voltage drop the held values are not restored by the HOLD function In this case the values are set to 0 OFF or a user defined program is executed ...

Page 10: ...rts the following RDM commands Parameter ID Discovery Command SET Command GET Command ANSI PID DISC_UNIQUE_BRANCH E1 20 DISC_MUTE E1 20 DISC_UN_MUTE E1 20 DEVICE_INFO E1 20 SUPPORTED_PARAMETERS E1 20 PARAMETER_DESCRIPTION E1 20 SOFTWARE_VERSION_LABEL E1 20 DMX_START_ADDRESS E1 20 DEVICE_LABEL E1 20 MANUFACTURER_LABEL E1 20 DEVICE_MODEL_DESCRIPTION E1 20 IDENTIFY_DEVICE E1 20 FACTORY_DEFAULTS E1 20...

Page 11: ...ype Manufacturer depending RDM control commands SERIAL_NUMBER PID 0xD400 Outputs a text description ASCII Text of the device serial number GET Send PDL 0 Receive PDL 21 21 Byte ASCII Text DISPLAY_AUTO_OFF PID 0xD401 Sets the time after which the display is switched off DISPLAY_LEVEL 0 Valid values are 0 NO AUTO OFF 600 1 minute 1200 2 minutes 1800 3 minutes 2400 4 minutes 3000 5 minutes 3600 6 min...

Page 12: ...Identify All outputs switch simultaneously ON OFF and the Status LED flashes 1 LOUD Identify The outputs switch ON OFF in sequence and the status LED flashes 2 QUIET Identify The outputs don t switch only the status LED flashes DMX_FAIL_MODE PID 0xD403 Sets behavior in case of DMX fail GET Send PDL 0 Receive PDL 1 1 Byte Function SET Send PDL 1 1 Byte Function Receive PDL 0 Parameter Function 0 Ho...

Page 13: ... user defined program COLOR_SEQUENCE PID 0xD413 Sets the used color sequence GET Send PDL 0 Receive PDL 1 1 Byte COLOR_SEQUENCE_ID SET Send PDL 1 1 Byte COLOR_SEQUENCE_ID Receive PDL 0 COLOR_SEQUENCE_ID Function 0 R G B 1 R B G 2 G R B 3 G B R 4 B R G 5 B G R ...

Page 14: ...he device and in case of DMX signal lost DMX Fail The program can be created with the free DMX Configurator software and then transferred with the free software RDM Configurator Both are available for free on our homepage Use only the latest version of the software DMX Configurator software at least V2 3 17 and RDM Configurator software at least V1 5 Execute after power on Program 1 New 1 executed...

Page 15: ...The program created in the DMX Configurator software must be saved in prg format Project Save as Then the created program is ready to trans to the DMX LED Dimmer XS3 with the RDM Configurator via the UPLOAD_PROGRAM parameter ...

Page 16: ...DMX LED Dimmer XS3 16 Factory Reset To reset the DMX LED Dimmer XS3 to the factory settings use the RDM parameter FACTORY_DEFAULTS ...

Page 17: ...DMX LED Dimmer XS3 17 Dimension all details in mm ...

Page 18: ...DMX LED Dimmer XS3 18 Accessories RGB LED Stripe 5m Power supply ...

Page 19: ... the EMC directive 2014 30 EU is necessary Disposal Electronical and electronic products must not be disposed in domestic waste Dispose the product at the end of its service life in accordance with applicable legal regulations Information on this can be obtained from your local waste disposal company Warning This device is no toy Keep out of the reach of children Parents are liable for consequenti...

Page 20: ...the board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it Operating risk The Change or the operation under special conditions of the installed systems components could as well as hidden defects cause to breakdown within the running time Misusage risk Any n...

Page 21: ...tems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely For this reason I see myself compelled to point out that I can take over neither a warranty nor the legal responsibility or any adhesion for consequences which decrease go back to incorrect data This document does not contain assured characteri...

Reviews: