![Quick BTR185 Installation And Use Manual Download Page 37](http://html1.mh-extra.com/html/quick/btr185/btr185_installation-and-use-manual_3766978037.webp)
EN
BTR185 INSTALLATION AND USE MANUAL - REV009A
37
BTR185
5 - Connection diagram
5.0 - BTR185 basic system
M1
A
A
S
S
SX
+
-
DX
-
M2
RTC R1
ELECTRONIC BOARD
BATTERY
12/24V
BATTERY ISOLATOR
BLACK
FUSE 4A
QUICK
ACTING F
FUSE
SEE TABLE
ON PAGE 26
SWITCH
RED
BLACK
RED
TO THE SERVICES
BATTERY
TCD 1042
TCD 1022
SPLITTER
(OPTIONAL)
CONTROL CABLE
EXTENSIONS
(OPTIONALS)
*
*
MOTOR
Connection example
TO THE SERVICES
BATTERY
ACTUATOR
SWITCH
*
1 2
4
6
5
3
7
FUSE 10A
QUICK ACTING F
*
COMMON NEGATIVE FOR THE BATTERY GROUPS.
** WARNING: IN CASE OF OVERTEMPERATURE, THE THERMAL PROTECTION ON THE MOTOR WILL OPEN AND INTERRUPT THE NEGATIVE CONTACT ON THE SOLENOID UNIT. WAIT AS LONG
AS THE SYSTEM NEEDS TO REACTIVATE.
** THERMIC
PROTECTION