3 - Introduction
• For improved safety we recommend installing at least two anchor windlass controls in case one is acciden-
tally damaged.
• We recommend the use of the Quick® hydraulic-magnetic switch as the motor safety switch.
• Secure the chain with a further device before starting the navigation.
• The contactor unit or reversing contactor unit must be installed in a point protected from accidental water
contact.
• Secure the rope with a further device before starting the navigation.
• To prevent accidental releases, the anchor must be secured. The windlass shall not be used as the only se-
curing device.
• Isolate the windlass from the power system during navigation (switch the circuit breaker off) and lock the
chain securing it to a fixed point of the boat.
• This device must not be used and installed by people (including children) with reduced physical, sensory
or mental capabilities. QUICK® SpA will not accept liability for direct or indirect damage caused by improper
use of the equipment.
PROCEEDING WITH THE INSTALLATION IN GOOD LIGHT CONDITIONS.
We recommend using an appropriate personal protective equipment.
Windlass is not suitable for being installed in highly explosive.
Assembly and subsequent checks or repairs must only be carried out by qualified personnel.
MAKE INSTALLATION / MAINTENANCE MAKE SURE THAT THE PRODUCT IS DISCONNECTED FROM THE
ELECTRICAL SYSTEM
Quick takes no responsibility regarding the inadequate connection of the users to the electrical system and to the
safety of the same.
3.1 Precautions for the installer
4 - Installation
A . WALL INSTALLATION
Ensure that the inner and outer surfaces of the wall are as parallel as possible. If this is not the case, compensate the
difference appropriately.
4.0 Installation requisites
F
Tighten the nuts with the
torque value indicated in
the table (cap.1.1 pag.4)