16
BL2
EN
INSTALLATION AND USE MANUAL QUICK
BL2
- REV003B
1 - Information about the product
(1) Minimum allowable value for a total length L<20m. Determine the cable size according to the length of the wiring
(2) With circuit breaker designed for direct currents (DC) and delayed-action (thermal-magnetic or hydraulic-magnetic).
MODELS
BL2 FF 6
Y
BL2 FF 9
BL2 FF 12
MOTOR OUTPUT
600W
900W
1200W
Motor supply voltage
12 V
24 V
12 V
24 v
12 V
24 V
Maximum working load
200 Kg (440,9 lb)
320 kg (705 lb)
420 kg (926 lb)
Maximum speed
25-28 m/min (82-91 ft/min)
22-25 m/min (72-82 ft/min)
28-30 m/min (91-98 ft/min)
Motor cable size (1)
16 mm
2
(AWG5) 10 mm
2
(AWG7) 25 mm² (AWG7) 10 mm
2
(AWG7) 35 mm² (AWG2) 16 mm² (AWG5)
Protection circuit breaker (2)
60 A
40 A
50 A
40 A
80 A
40 A
Weight
9,7 Kg (21.34 lb)
14,6 kg (32.2 lb)
17 kg (37 lb)
1.1 - Technical data
1.0 - Model code
F
MODEL
POWER
(W)
MOUNTING
(DX / SY)
FREE FALL
OUTPUT (V)
BL2 6 12
F
Y
Indicative values, evaluate the tightening considering the material of the surfaces to be fixed.
(3) The values in the table refer to a three-strand polyester rope with a rope/chain splice manufactured with the “Quick®” system.
(*) Gypsy codes, see engineering drawings on page 13
(**) ISO EN 818-3.
BARBOTIN
6 MM
7 MM / 1/4"
8 MM
5/16"
CHAIN SIZE
6 mm
6 mm
7 mm
7 mm
1/4"
1/4”
8 mm
8 mm
5/16”
ISO
DIN 766
DIN 766
ISO (**)
G4
BBB
DIN 766
ISO (**)
G4
ROPE SIZE
(3)
1/2" (12,7 mm)
1/2" (12,7 mm)
1/2" (12,7 mm)
1/2" (12,7 mm)
1/2" (12,7 mm)
TIGHTENING TORQUE
Nm
M6
11
M8
28
M10
56
M12
96
M14
152
M16
237
QUICK® RESERVES THE RIGHT TO INTRODUCE CHANGES TO THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
IN CASE OF DISCORDANCE OR ERRORS IN TRANSLATION BETWEEN THE TRANSLATED VERSION AND THE ORIGINAL TEXT IN THE ITALIAN LANGUAGE,
REFERENCE WILL BE MADE TO THE ITALIAN OR ENGLISH TEXT.