background image

 

 

QC-PC-PID-01 

 

Peltier-Controller 

 

 

Manual 

Summary of Contents for QC-PC-PID-01

Page 1: ...QC PC PID 01 Peltier Controller Manual...

Page 2: ...SWORD MENU 12 Safety query 13 PARAMETER MENU 14 PA SET MENU 16 Software Version 17 Controller connection 18 Before start up 19 First commissioning step by step 20 Switch off current flow 20 Parameter...

Page 3: ...2 04 10 2021 20210927 QC PC PID 01 Bedienungsanleitung engl Quick Ohm K pper Co GmbH Cronenfelder Stra e 75 42349 Wuppertal Germany www quick ohm de www quick cool de...

Page 4: ...ional output signal 0 10VDC max 80mA Open Collector output Imax 100mA Emitter on ground Intended use and description of the controller The QC PC PID 01 is used for controlling temperature The controll...

Page 5: ...ments have their imprint on the cold side The object to be tempered must be thermally coupled to the cold side The other side must be thermally coupled to a heat sink If a voltage is applied to the co...

Page 6: ...nsor The hot side must contact a heat sink over the entire surface The heat sink must be able to dissipate the thermal energy without the hot side heating up excessively The complete structure has to...

Page 7: ...nderstood The controller may only be connected to a professional installed system Before switching on make sure that the maximum permissible current of 8 amperes cannot be exceeded The data sheet of t...

Page 8: ...leitung engl The user interface Menu After applying the supply voltage the monitor menu is displayed on the touchscreen All important values and various states of the controlling are visualized here F...

Page 9: ...t and the free air supply If the board temperature exceeds a critical value the colour changes to red and the control switches off The controller can only be restarted when the board temperature has r...

Page 10: ...01 Bedienungsanleitung engl Bar display Control value display tacho The bar indicates the current status of the control system up red Heating Full deflection at maximum heating down blue Cooling Full...

Page 11: ...EMPERATURE flashes when the SETPOINT MENU is entered The regulation is maintained with the previously selected target temperature Changed values are only accepted when you exit the setpoint menu incre...

Page 12: ...t flashes after entering the PASSWORD MENU increases the flashing digit decreases the flashing digit jumps to the next digit jumps into the PARAMETER MENU only if the correct password was entered befo...

Page 13: ...new password flashes when the CHANGE PASSWORD MENU is reached increases the flashing digit decreases the flashing digit jumps to the next digit jumps to the Safety query aborts the process and returns...

Page 14: ...query The security query protects against unwanted password changes changes the password and jumps to the PARAMETER MENU The new password is set The old password is no longer valid aborts the process...

Page 15: ...actual value are continuously displayed so that the control can continue to be monitored The parameterization can be evaluated based on the temperature and readjusted if necessary These two jump butto...

Page 16: ...ACT TEMP actual temperature shows the actual temperature measured at the sensor TAR TEMP target temperature shows the set target temperature TEC CUR shows the current flow through the connected eleme...

Page 17: ...of the stored parameter sets into the current memory using With you get back to the PARAMETER MENU Attention only the control parameters KP TN and TV are stored here The PM value is not saved ACTUAL P...

Page 18: ...7 04 10 2021 20210927 QC PC PID 01 Bedienungsanleitung engl Software Version Here you get the information about the software version Touching the centre of the display switches back to the MONITOR men...

Page 19: ...lso Correct polarity of the Peltier element 2 bk PE Peltier element connection Black wire 3 Vsupply Connection positive voltage supply 12 VDC 24 VDC 4 Vsupply Connection GND potential zero voltage sup...

Page 20: ...old side of the Peltier element The object to be tempered must have good thermal connection with PT1000 sensor On the other hand the entire hot side must be connected to a sufficiently effective heat...

Page 21: ...RE value If an unrealistic temperature is displayed switch off the supply voltage and please check your assembly and the sensor The controller may only be operated with a PT1000 sensor Switch off curr...

Page 22: ...controller output to the load Without a correct adjustment both the connected consumer and the controller can be destroyed The PM determines the maximum allowable supply voltage to be set as output t...

Page 23: ...voltage Connect the red wire of the Peltier element to terminals 1 and the black wire to terminal 2 Check your assembly Switch on the supply voltage You are now in the MONITOR menu and the operation i...

Page 24: ...asured temperature is equal to the set target temperature the output is regulated to zero Therefor the setpoint can never be reached in the P control mode The larger the KP value the stronger the cont...

Page 25: ...d and warm sides of the Peltier element In addition these two performance values are very different from each other This means that the parameterization of the Peltier control differs from conventiona...

Page 26: ...has pure P characteristics Set T1 to a value just about 10 Kelvin above TMedium Set T2 to a value just about 10 Kelvin below TMedium Confirm the changes Touch the area jump to target1 Observe the tem...

Page 27: ...2 as well as 7 8 9 and 10 remain open Switch on the supply voltage Check temperature value Check the operating indicator light switch off if necessary Switch to the parameter menu Determine and set PM...

Page 28: ...op right bottom left bottom right the controller is reset to the factory setting An existing password is hereby deactivated and reset to 0000 Do this if you have lost the password The individual keyst...

Page 29: ...28 04 10 2021 20210927 QC PC PID 01 Bedienungsanleitung engl Drawings Peltier controller...

Page 30: ...29 04 10 2021 20210927 QC PC PID 01 Bedienungsanleitung engl PT1000 Sensor Stainless steel sleeve Connection cable silicone 200 C...

Page 31: ...________________________________________________ _________________________________________________________________________________ _____________________________________________________________________...

Page 32: ...________________________________________________ _________________________________________________________________________________ _____________________________________________________________________...

Reviews: