Quest Dry 132D:

•  Low dewpoint operation
•  132 Pints/Day @ AHAM
•  Wide operating range
•  24 Amps total power consumption
•  Factory installed 115VAC power cords  

(2 required @ 15 Amps each)

•  Simple ON/OFF operation with optional  

low voltage control for remote/dehumidistat operation

•  Vertical or horizontal operation
•  Multiple ducting options

Water Removal Rates (Pints/Day) 

 

65 Pints    

100°F, 20% 

180 Pints   

90° F, 90% 

150 Pints   

80° F, 80% 

132 Pints  

80° F, 60% (AHAM)

 

130 Pints   

70° F, 80% 

120 Pints   

70° F, 60% 

120 Pints   

60° F, 80% 

115 Pints    

60° F, 60% 

125 Pints   

50° F, 80% 

100 Pints  

50° F, 60% 

30 Pints    

10° F, 80%

4201 Lien Rd 

Phone 608-237-8400

Madison, WI 53704 

Toll-Free 1-877-420-1330

www.QuestHydro.com [email protected] 

Specifications subject to change without notice.

1

TS-1030

10/17 Rev. A

Quest Dry

Quest Dry 132D

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions

Summary of Contents for Dry 132D

Page 1: ...ion Factory installed 115VAC power cords 2 required 15 Amps each Simple ON OFF operation with optional low voltage control for remote dehumidistat operation Vertical or horizontal operation Multiple ducting options Water Removal Rates Pints Day 65 Pints 100 F 20 180 Pints 90 F 90 150 Pints 80 F 80 132 Pints 80 F 60 AHAM 130 Pints 70 F 80 120 Pints 70 F 60 120 Pints 60 F 80 115 Pints 60 F 60 125 Pi...

Page 2: ...side Drying Space 5 3 Operation 5 3 1 How the Quest DRY 155 Works 5 3 2 Controlling the Quest Dry 132D 6 4 Maintenance 6 4 1 Air Filters 6 4 2 Blower Motors and Rotor Drive Motor 7 4 3 Desiccant Rotor Cassette Assembly 7 5 Service 7 5 1 Warranty 7 5 2 Technical Description 7 a Main Components 7 b Control Circuit 8 c Safety Components 8 5 3 Normal Operation 8 5 4 Troubleshooting 8 6 Wiring Diagram ...

Page 3: ...rk passes through a cold space the duct must be insulated to prevent condensation from forming inside the duct Le Quest Dry 132D est conçu pour être installé SEULEMENT À L INTÉRIEUR Lorsqu utilisée près d une zone d eau l unité doit être branchée sur des circuits DDFT N UTILISEZ PAS le Quest Dry 132D comme banc ou table Évitez d évacuer l air de procédé directement vers les gens Cet appareil ne do...

Page 4: ... Reactivation Duct 6 Start collars included Process Duct 8 Start collars included External Static 0 0 4 WC Process Pressure 0 0 25 WC Reactivation Warranty 1 Year Parts and Labor Low temperature performance is dependent on reactivation air source Supplying warmer reactivation air will significantly increase water removal Dimensions Unit Shipping Width 20 25 Height 36 47 Depth 20 24 Weight 105 Lb 1...

Page 5: ...ing spaces Keeps separation between air inside and air outside of drying space c Outside Drying Space Requires process air to be ducted out from and back into drying space Works well if drying space is too small for mounting unit inside Reduces heat load on drying space 3 Operation The Quest Dry 132D comes complete and can be plugged in and turned on Connected this way the Quest Dry 132D will run ...

Page 6: ...tched on the unit will run When the terminals are not electrically connected the unit will not run Remove the factory installed jumper before installing an external control If the jumper is not removed the Quest Dry 132D will operate continuously as described in 3 2 a IMPORTANT Line voltage controls that interrupt power to the unit may not be used with the Quest Dry 132D The unit uses an internal ...

Page 7: ...f removal Cassette Removal Instructions 4 0 6 1 RELAY 2 4 0 6 1 LOW V RELAY 4 0 6 1 24VAC TRANSFORMER GRN TRANSFORMER PRIMARY EXTERNAL CONTROL TRANSFORMER SECONDARY 3ABREAKER LOW V RELAY COIL TERMINAL BLOCK EXTERNAL CONTROL 3A BREAKER 1 2 4 2 Blower Motors and Rotor Drive Motor All motors on the 132DD are permanently lubricated and do not require maintenance 4 3 Desiccant Rotor Cassette Assembly T...

Page 8: ...n inlet temperature is too high or if there is insufficient reactivation airflow the automatically resetting heater cutout opens and all loads are de energized Once the temperature drops by a few degrees F the switch closes again and the loads are re energized The second heater cutout has a higher temperature limit and only trips if the automatically resetting switch hasn t opened This higher cuto...

Page 9: ... No continuity across low voltage control terminals 4 Thermal cutout s tripped Unplug unit and allow to cool Identify and correct problem before plugging unit back in 5 Defective relay s 6 Wiring fault inside device Blowers and heater operating rotor not turning 1 Rotor unplugged 2 Belt broken or not properly tensioned Adjust or replace belt 3 Pulley not fixed to driveshaft Tighten or replace set ...

Page 10: ...RG 31 YEL 20 RED 18 VIO 15 VIO 27 BLK 2 BLK 10 VIO 14 WHT 13 WHT 22 WHT 23 BLU 21 BLU 7 BLU 25 BLU 25 YEL 19 VIO 33 ORG 30 YEL 32 BLK 17 BLK 1 BLU 29 BLU 21 TERMINAL BLOCK WHT22 BLK28 WHT 23 1 2 3 4 LINE LINE ROCKER SWITCH POLE 1 ROCKER SWITCH POLE 2 NEUTRAL 24VAC COM NEUTRAL RELAY 1 CONTACT LOW V RELAY CONTACT 1270W HEATER 1360W HEATER HEATER CUTOUT 1 RELAY 2 COIL PROCESS CAPACITOR HEATER CUTOUT ...

Page 11: ...T BREAKER 4022484 RELAY SPST 24VAC COIL 4022487 TRANSFORMER 120V 24V 40VA 18 1 800 533 7533 Quest DRY 115 Installation Operation and Maintenance Instructions www thermastor com sales questprotect com quest Asset Protection and IAQ Solutions quest 9 0 8 5 6 Service Parts List Item Part No Description 1 4025076 FAN MOTORIZED IMPELLER PROCESS AIR 2 4025224 CAPACITOR RUN 15 MFD 370V DRY PROCESS AIR 3 ...

Page 12: ... tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC reasonable control Limitations and Exclusions If any Quest Dry 132D Dehumidifier part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period applicable thereto but all warranty periods will be extended by t...

Reviews: